Nibe GBM 10-15 Manuel D'installation Et D'utilisation page 83

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Heat on/off
TERM.
Chaleur arche/arrêt
BOLL.
Heizbetrieb Ein/Aus
Zap./Vyp. ohřevu
Zap./Vyp. ohrevu
Podgrzewanie wł./wył.
Varme on/off
M2
7
CN9
V Lv
4
1
CN10
1
3
CN8
EN
L-N POLARITY IS RECOMMENDED
MULTIWIRE WIRING DIAGRAM
Blu=Blue
/
Marrone=Brown
Rosso=Red/ Bianco=White / Viola=Violet / Rosa=Pink
/ Arancione=Orange / Grigio=Grey / Giallo=Yellow /
Verde=Green
A = Gas valve
B = Fuse 3.15A F
AKL Control board
P1
Potentiometer to select off - on service area
P2
Potentiometer to activate chimewy function
P3
Not used
P4
Not used
JP1
Calibration
JP2
Don't use
JP3
Calibration
JP4
Don't use
JP5
Jumper must be inserted
JP6
Don't use
JP7
Don't use
JP8
Do not use
LED LED 1 (green) to indicate operating status or
temporary shutdown
LED 2 (yellow) to indicate preheating is ON and
chimney sweep function
PWM Signal
PWM Signal
Segnale
PWM Signal
PWM
Signál PWM
Signál PWM
Sygnał PWM
PWM Signal
P.A.
B
VALVOLA GAS
2
3
OPE
OPE
1
1
2
3
4
1
2
3
4
5
rosa
1
CN2
6
T.L.A.
V Hv
CN3
2
1
12
VIS MEDIUM
J1
1
4
J1
LED 3 (red) to indicate permanent lockout status
CN1-CN15 Connectors
/
Nero=Black
/
(CN6 control panel /outer sensor kit – CN7 lo-
cal valve kit) -
CN5 room thermostat (24 VDC)
S.W.1 Chimney sweep function, interruption of pur-
ge cycle and calibration when enabled.
E.R. Flame detection electrode
F1
Fuse 3.15A T
F
External fuse 3.15A F
M2
Terminal board for heating on/off
M3
Terminal board for external connections
UPM Pump
OPE Gas valve operator
V Hv Fan power supply 230V
V Lv Fan control signal
E.A. Ignition electrode
TSC2 Ignition transformer
P.A.
Water pressure switch
T.L.A. Water limit thermostat
S.F.
Flue gas probe
S.M. Delivery temperature sensor on primary circuit
S.R. Return temperature sensor on primary circuit
J1
Connectors
VIS MEDIUM Digital monitor
marrone (+)
UPM
blu (-)
230 V
N L Fusibile 3.15A F
M3
F
1
S.M.
S.R.
-t°
-t°
S.F.
-t°
1
CN11
83
C
1
CN15
JP6
JP7
JP5
JP4
CN6
CN7
CN5
P4
5
JP8
SW1
1
CN13
CN8
3
P1
L3
L2
CN14
P3
L1
1
AKL
CN9
7
1
3.15A T
CN10
F1
4
1
CN11
12
FA2
FA1
S.C.
E.R.
TSC2
N
F
E.A.
1 2
3
CN1
F
UNE POLARITÉ L-N EST RECOMMANDÉE
Diagramme de câblage multifi ls
Blu=Bleu
/
Marrone=Marron
Rosso=Rouge/
Bianco=Blanc
Rosa=Rose / Arancione=Orange / Grigio=Gris /
Giallo=Jaune / Verde=Vert
A = Vanne de gaz
B = Fusible 3,15A F
AKL Carte de commande
P1
Potentiomètre pour sélectionner l'arrêt-la mar-
che de zone de service
P2
Potentiomètre pour activer la fonction che-
minée
P3
Non utilisé
P4
Non utilisé
JP1
Réglage
JP2
Non utilisé
JP3
Réglage
JP4
Non utilisé
JP5
Le cavalier doit être inséré
JP6
Ne pas utiliser
JP7
Ne pas utiliser
JP8
Ne pas utiliser
LED LED 1 (verte) indique l'état de fonctionnement
ou l'arrêt temporaire
JP2
CN12
JP3
JP1
P2
3
CN4
1
2
CN3
1
6
CN2
1
CN1
1
fi g. 4
/
Nero=Noir
/
/ Viola=Violet
/