Fault:
Battery is not charged despite illuminated
green LED on charger
Possible cause:
– Battery too cold or too warm (one red
LED illuminates on battery)
Remedy:
– Warm up battery or allow to cool
(
8.4). Store the charger in a closed
and dry place at a temperature of
between +5°C and +40°C only.
Fault:
Battery is not charged, no LED illuminates
Possible cause:
– No electrical contact between charger
and battery
– Charger power supply faulty
Remedy:
– Remove battery from battery
compartment and reinsert (
– Connect charger to the mains (
– Check mains power supply
– Check charger, replace if necessary
( )
Fault:
LED on charger flashes red
Possible cause:
– No electrical contact between charger
and battery
– Battery defective (4 LEDs on battery
flash red for approx. 5 seconds)
– Charger defective
Remedy:
– Remove battery from battery
compartment and reinsert (
– Check battery, replace if necessary ( )
– Check charger, replace if necessary
( )