Cleaning the condensator and the evaporator

Because these components are only accessible when the unit's housing has
been opened, both parts may only be cleaned by an authorised dealer !
• The condensator and the evaporator may only be cleaned with a soft brush
or by blowing or sucking air. Do NOT spray or clean with water.
• The evaporator fins and the parts themselves are very sensitive and
can be easily bent or otherwise damaged.
• The interior surfaces of the unit, the condensate tray, the fan and
the fan housing must be cleaned carefully.
• It must be ensured that the parts that were previously dismantled
are all properly put back together again.
• Check the unit to ensure that it works properly and check the
electrical system to ensure that is safe.

Important information regarding the disposal of this unit !

The unit is operated with the environmentally-friendly, ozone-neutral refrigerant
R-407C. The refrigerant /oil mixture in the unit must be disposed of in a safe
way in accordance with local and national regulations and guidelines.
Please dispose of this appliance in a manner appropriate to the
relevant legal requirements at the end of its product life.
11. Troubleshooting
The unit was subjected to stringent testing during production and before it left
our premises. Please check the product you have bought using the list below
should you encounter any problems.
The unit will not start up:
• Check the mains power supply. 230 V / 1~ / 50 Hz.
• Check the main fuses in the building.
• Check the mains plug to make sure that it not damaged.
The unit is running but there is no condensate forming:
• Check the room temperature. The unit's operating range is
between 5 and 32 °C.
• Check the relative humidity. It must be at least 40 % RH.
• Check the preselected value. The relative humidity in the room in which
the dehumidifier has been installed must be higher than the selected value.
Lower the preselected value, if necessary (see chapter 07, "Selecting the
desired relative humidity value").
• Check the air intake filter to see that it is not heavily soiled or damaged.
Clean or replace if necessary.
• The exchanger fins may have to be checked to see if they are heavily
soiled. Because these components are only accessible when the unit's
housing has been opened, the parts may only be cleaned by an
authorised and certified specialist dealer !
Disconnect the plug from the mains BEFORE any work
is a carried out on the unit !
B 5
The unit is very loud or has started to vibrate;
condensate is running out of the unit:
• Check to ensure that the unit is standing on a flat and level surface.
• Have the condensate tray and the connecting piece checked to see
if they are heavily soiled.
Please contact an authorised dealer if the unit still does not work properly despite
the checks that you have carried out.
12. Technical Data
Temperature operating range
Relative humidity operating range
Dehumidification performance 24 h max.
Dehumidification performance 24 h (at 30 °C / 80 % RH)
Air flow rate max.
Refrigerant
Refrigerant quantity
Connection voltage
Nominal current max.
Power input max.
Noise level LpA 1m
Length *
Width *
Height *
Weight
1)
Noise measurement DIN 45635 - 01 - KL 3
* without handle and wheels
Operating Instructions Dehumidifier TTK 650 S-EH
Any work that has to be carried out on the refrigerant unit
or the electrical circuits may only be performed by an
authorised and certified specialist dealer !
1)
5 - 32 °C
40 - 90 % RH
150 litres
123 litres
1,480 m³/h
R-407C
1.15 kg
230 V / 50 Hz
6 A
1.8 kW
56 dB (A)
540 mm
640 mm
850 mm
50 kg
EN