F. TechNicAL seRVice, ORigiNAL sPARe PARTs
before leaving the factory, each stove has been carefully tested and commissioned.
Any repairs or commissioning that may become necessary during or after installa-
tion must be carried out by heating engineers authorized by Zibro. original factory
spare parts can be obtained only and exclusively from our technical servicing cen-
ters and authorized points of sale.
When contacting your dealer, the technical service centre or the authorized hea-
ting engineer, first make sure to be able to specify the model and serial number at
their first request.
only use by Zibro agreed spare parts. using non Zibro spare parts will lead to nul-
lification of the warranty.
g. TROUbLe shOOTiNg
Problem
problems during start-up
condensation forms
smoke leaks out of the stove
glass gets too dirty
4
54
Possible cause
Wood size is too big
Wood is too humid
not enough draught in the chim-
ney
there is not enough fresh air sup-
plied to the room
too much draught
chimney flue section is too large
chimney flue is not insulated well
combustion is too slow
chimney flue is not insulated well
unfavourable weather conditions
(too strong wind)
unfavourable
weather
conditi-
ons, (too little wind, misty/foggy
weather conditions)
Wood is too humid
charging door seal is damaged or
worn out
not enough draught in the chim-
ney
Wood is too humid
combustion is too slow
fuel is of poor quality
Possible solution
use very dry small wood sticks be-
fore larger size wood
use seasoned (dry enough) wood
turn all settings to maximum ope-
ning and check that the chimney
flue is not obstructed.
check if chimney shut off damper
is fully opened
immediately provide an aeration
grid, please refer to an authorized,
specialised heating engineer.
primary air inlet to minimum
Reduce the chimney flue section
using thermally insulated pipes
(needs to be done by specialised
heating engineer, such as for
example a chimney sweeper or
chimney installer)
line the chimney flue with insula-
ting material (only by authorized
professional)
open air parameters to increase fire
and temperature of outlet fumes
line the chimney flue with insula-
ting material (only by authorized
professional)
chimney pot is not wind protected,
(re-)place it.
this is normal, operating the stove
at these weather conditions should
be avoided.
use seasoned, dried wood
have charging door seal replaced
by authorized technician
turn all settings to maximum ope-
ning and check that the chimney
flue is not obstructed (needs to be
done by specialised heating engi-
neer, such as for example a chim-
ney sweeper)
use seasoned, dried wood
open air parameters to increase fire
and temperature of outlet fumes
use fuel as described in paragraph
d.3