Volum
Description
PrnTy
Printer type Select the printer mod-
el installed.
Valid only if GateT=In
PrnOF
Offset value to adjust the printer's
ticket cut
ScnTy
Scanner type Select the scanner
model installed
HeaTh
Temperature
which the heating resistor turns on.
LoopT
Time between loops It defines the
maximum number of seconds be-
tween the detection loop clearing
and the safety loop triggering.
INPUT
It shows the status of the digital in-
puts connected to the station
Temp
Current temperature In °C
Emit Test
Test ticket printing. Press the joy-
stick to print a test ticket.
Ticket
WIEG:
125KHz season ticket reading func-
tion Bring a card up to the reader to
check the code.
WARNING! Any parameter modification must be performed in compliance with the instruc-
tions in this manual.
WARNING! Restart the station so that the modifications become effective.
40 - Espas30 I
threshold
below
Values
KPM=Custom KPM printer
KPMH=Custom KPMH printer
X56=Hengstler X56 printer
0...255
Valid only for KPM and KPMH
printers
Dacom=2D scanner
Quantum=EAN13 Laser scanner
0...255
1...30
VALUES:
0. ticket request button
1. single entry
2. photocell fitted
3. input for general purposes
4. presence of the detection loop
5. presence of the safety loop
6. closed barrier input
7. disabling input
Default