EXPERT SETTINGS

ACCESS

You access to expert settings in 5 steps.
From Auto, Comfort, Eco or Frost protection mode :
Information display
1
Press for 5
seconds
Information display
Setting sequence:

Ambient temperature sensor adjustement

AMBIENT TEMPERATURE SENSOR ADJUSTEMENT
Overview
Important: This operation is reserved for professional installers only;
any wrong changes would result in control anomalies.
In which case if the temperature measured (measured by reliable ther-
mometer) is different by at least 1°C or 2°C compared to the setting
temperature of the radiator.
The calibration adjusts the temperature measured by the ambient tem-
perature sensor to compensate for a deviation from + 5°C to - 5°C by
intervals of 0.1°C.
Ambient temperature sensor adjustement
1- If the room temperature difference is negative, example :
Setting temperature (what you want) = 19°C.
Ambient temperature (what you read on a reliable thermometer) =
18°C.
Difference measured = -1°C.
Important: Before carrying out the calibration it is recommended to
wait for 4h after the setting temperature modification to insure that
the ambient temperature is stabilized.
To correct, then proceed as follows :
Sensor temperature = 21°C
(The measured temperature may be different due to the location of the
thermostat in the room).
2
1
Press briefly
twice
4
Long and simultaneous
10 seconds press
Internal temperature monitoring
Information displays
1
Pro
= Expert settings
Hysteresis adjustment
Decrease the temperature measured by the ambient temperature sen-
sor by 1°C by pressing
In our example the measured temperature by the sensor goes
from 21°C to 20°C.
2- If the room temperature difference is positive, example :
Setting temperature (what you want) = 19°C.
Ambient temperature (what you read on a reliable thermometer) =
21°C.
Difference measured = +2 °C.
To correct, then proceed as follows :
Sensor temperature= 21°C.
(The measured temperature may be different due to the location of the
thermostat in the room).
5
Press briefly
Restoring factory settings
.