9- To save and move automatically to the next setting, press
To exit the user settings, press
SETTING OF THE MAXIMUM AMBIENT
TEMPERATURE DURING BOOST
When the Boost is enabled in Auto, Comfort, Eco or Frost protection
mode, the blower has to heat the room until the temperature limit: the
maximum ambient temperature.
When it is reached, the blower stops automatically and restart to main-
tain this temperature until the end of Boost period.
It is preset at 25°C, you can adjust it from 20°C to 35°C by intervals of
1°C.
The Boost symbol and the heating indicator appear on the display and
the maximum temperature flashes.
14- You can set the Boost maximum temperature by pressing
from 20°C to 35°C by intervals of 1°C.
15- To save and move automatically to the next setting, press
exit the user settings, press
twice.
twice.
.

RESTORING FACTORY SETTINGS

In order to a coming back to factory settings, proceed in the following
order:
1- From the previous setting, press
NO
2-
appears. Press
yes
= Factory settings reset
or
NO
= Factory settings not reset
EN
3- Press the key
guration and goes back automatically to the home display of the user
settings.
. To
The following factory values will be effective:
Parameters
Comfort setting temperature
Eco setting temperature
Boost duration
Keypad lock
Backlighting
Frost protection temperature
Maximal Boost duration
Maximum ambient temperature
for the automatic stop of the
Boost
Press
to exit the user settings.
rest
.
appears on the display.
YES
or
to select
for 5 seconds. The device returns to its initial confi-
Factory settings
Operating
19°C
15°C
60 min.
Disabled
User settings
L3
7°C
60 min.
25°C
M16MI325 A03_06/18
EN
.
5 sec.