4.1 INSTALLATION EXAMPLE

Connecting multiple receivers to the same polarity:
The number of receivers that is possible to connect to the same polarity depends by the frequency of
the trasponder to receive and by the level of input signal. It is recommended to program the channels
with the highest input frequencies on the first receivers of the headend. Use a splitter to divide the
cable from the dish in case the signal is too low at the last input receivers, in order to reduce the loop-
through losses.
To distribution network
Using a multiswitch to distribute signal to different receivers:
To distribution network