Télécharger Imprimer la page

Honeywell VisionPRO IAQ Guide D'installation page 8

Masquer les pouces Voir aussi pour VisionPRO IAQ:

Publicité

Les langues disponibles

Les langues disponibles

Installation Guide
Installer setup
Setup functions
0700
Temperature
display offset
0701
Humidity
display offset
0710
RESET
Special functions
Auto Discover: Setup functions set to "E" (Auto Discover) will be configured automatically,
based on information sent by the Equipment Interface Module.
Adaptive Intelligent Recovery (Setup Function 0530): Allows the thermostat to "learn" how
long the furnace and air conditioner take to reach programmed temperature settings, so the
temperature is reached at the scheduled time.
Compressor Protection (Setup Function 0580): Forces the compressor to wait a few minutes
before restarting, to prevent damage. During this time, the message "Wait" flashes on the display.
Southern Away Dehumidification Control (Setup Functions 0390-0394): This feature is useful
for homes in southern climates. It allows humidity control when the the home is unoccupied for
long periods during the hot/humid season. You can control temperature (Function 0393) and
dehumidification (Function 0394) while away. You can control humidity with a dehumidifier or a
cooling system (Function 0379). If a cooling system is used, humidity is controlled by cooling
indoor air to the Low Limit Temperature (Function 0392). When the desired humidity is reached,
the system will maintain the temperature you select in Function 0393.
Heat Pump Control — Electric Backup (Setup Functions 0350-0360): If an outdoor tempera-
ture sensor is installed, select a compressor lockout temperature (Function 0350). Below this
temperature, only electric heat operates. Also select an auxiliary lockout temperature (Function
0360). Above this temperature, only the compressor operates. Between these temperatures,
both heat sources operate.
Heat Pump Control — Fossil Fuel Backup (Setup Function 0345):
Option 0 (Balance point only): If outdoor temperature is above balance point (Function 0350),
only the compressor operates. Below this temperature, only backup heat operates.
Option 1 (Balance point + 2°F droop): As above, but backup heat is activated if room tempera-
ture drops by 2°F (compressor is deactivated).
Option 2: (Balance point/Aux Heat +2°F droop): Compressor works only above auxiliary lockout
temperature, backup heat works only below balance point, 2°F droop between temperatures. If
temperature is not reached in a reasonable time, set the upstage timer (Function 0346). After
the designated time, the compressor will be deactivated and the system will switch to backup
heat.
Ventilation Control (Setup Functions 0400-0406): If the system includes a self-powered venti-
lation unit (Function 0400), the home can be ventilated on demand, or ventilated automatically
if high humidity is detected while in heating mode (Function 0406).
(English: Page 4 • Français: Page 10 • Español: Página 16)
Settings & Options
0 Thermostat displays actual room temperature
[Other options: -3°F to +3°F offset (-1.5°C to 1.5°C)]
0 Thermostat displays actual room humidity
[Other options: -5% to +5% offset]
0 No reset
1 Reset installer options & program schedule to factory
default (only date and time settings are retained)
(factory default in bold)
8

Publicité

loading