WARNING
– Improper connection of the equipment-
grounding conductor can result in a risk of electrical shock.
Check with a qualified electrician or service person if you
are in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the appliance – if it will
not fit the outlet, have a proper outlet installed by a qualified
electrician.
WARNING
Hazardous Voltage. Shock or electrocution can
result. Unplug machine before servicing.

GB.3 MODIFICATIONS

Note:
We would like to point out that only original parts
and accessories are to be used. Failure to adhere
to these recommendations could result in
machine failure and damage that will not be
covered by the appliances warranty. Damaged
equipment could also result in injury to persons.
The manufacturer, its distributors and agents
cannot be held responsible at all for any damage
or injury whatsoever, caused by the improper use
of the appliance, unauthorized use, unauthorized
modifications or non-original spares.

GB.4 MACHINE COMPONENTS

1
Hose connector
2
Bent tube
3
Hand tube
4
Tank coupling
5
Nozzle
6
Cover
7
Handle
(02-02)
:
Home
Find...
Go To..
Vacuum cleaner/ Aspirateur à poussière/ Aspiradora
8
Opening spring
9
On/ Off switch
10
Power supply cord

GB.5 MACHINE INSTALLATION

GB.5.1
Machine contents
Carefully check carton for signs of damage. Report damages to
carrier immediately.
Check machine contents to ensure carton is complete. Contact
distributor for missing items.
Machine contents:
Tank
Cover with handle
Filter cartridge (inside tank)
Paper filter bag (inside tank)
Exhaust filter (pre-installed)
Hand tubes (two pieces)
Bent tube
Flexible suction hose
Nozzle.
GB.5.2
Assembly of the suction hose, hand tubes
and nozzle:
WARNING
Hazardous Voltage. Shock or electrocution can
result. Unplug machine before servicing.
Holding the rubber cuff of the suction hose coupling, insert it
into the tank coupling and rotate it clockwise.
Assemble the two hand tubes and bent tube by simply pushing
them together. Now fit the nozzle to the lower end of the hand
tubes and connect the end of the suction hose to the bent tube.
Note:
The length of the wand may be adjusted to suit
the operator. Simply remove the bent tube, turn it
around and reinsert it into the straight section.

GB.6 MACHINE SETUP

Ensure that the paper filter bag and filter cartridge are in the tank of
the machine and correctly positioned. Always ensure that filters are
clean and that the suction hose, wand and nozzle are not blocked.

GB.7 MACHINE OPERATION

FOR SAFETY:
Do not operate machine unless operator
manual is read and understood.
Connect the plug to the main supply and switch the machine on
by depressing the ON/OFF switch.
Begin vacuuming floor. Operate machine with a back and forth
motion.
Taking off wand and floor nozzle, the end of the flexible tube
can be used as a upholstery tool or crevice nozzle.
To stop vacuuming, switch the machine off by depressing the
ON/OFF switch.
Disconnect the plug from the main supply wall socket. Do not
pull on the cord as it may be damaged.
Always wind up the cord and hang it on the handle/cord hanger
on the top cover of the machine.