Télécharger Imprimer la page

Maintenance And Size Change - FAR EB 311 Mode D'emploi

Outil a riveter sur batterie

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
EB 311
MAINTENANCE AND SIZE CHANGE (fig. f4-f5-f6)
A prolonged use of the riveting tool could cause the deposit of
waste that may lead to the slipping of the clamps on the nail or
the ongoing working of the riveting tool due to the safety device
designed to preserve the integrity of the mechanical parts.
In this instance, remove the battery and clean inside the sleeve
carrying nozzle (B) and the clamps (M).
In case of wear of the clamps, replace them.
Use a 27-mm commercial wrench to remove the tube carrying
nozzle (B). Once the tube has been removed, use a commercial
wrench - 16 mm - to remove the cone (L) and extract the clamps
(M). To replace the nozzle (A), use the supplied special key (N)
and place on it the removed nozzle to avoid any loss.
Please note: prolonged use of the riveting tool may cause a
normal wear of the microswitch, of the motor or of the printed-
circuit board inside the handgrip. To avoid a further damage of
the tool, proceed in replacing the microswitch, the motor or the
printed-circuit board (see following chapters).
WARNING!
The riveting tool must be shut off during the
above operations.
f4
B
B
Revisione - 03
Revisione - 06
GB
f5
L
L
f6
A
A
Date 11-2016
Date 06-2011
M
WARNING!
WARNING!
The non-locking of the clamps holding
If the clamps holding cone is not well
cone could cause the continuous
locked, the riveting tool may be seriously
operation of the riveting tools.
damaged.
N