INSTALLATION

General

Glo-Ray
Designer Merchandising Warmers are shipped
®
with most components pre-assembled. Care should be taken
when unpacking shipping carton to avoid damage to unit and
components enclosed.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate the unit indoors where the ambient air temperature
is a minimum of 21°C (70°F).
FIRE HAZARD: Do not install unit above or around
combustible surfaces. Discoloration or combustion
could occur. Unit must be installed in non-combustible
surroundings only.
CAUTION
Locate unit at the proper counter height in an area that is
convenient for use. The location should be level to prevent
the unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
The National Sanitation Foundation (NSF) requires that
units over 36" (914 mm) in width or weighing more than
80 lbs. (36 kg) either be sealed to or raised above the
installation surface. If unit cannot be sealed at the point
of use, 4" (102 mm) legs are included to allow for proper
cleaning access below unit.
Transport unit in upright position only. Before moving or
tipping unit, secure all glass surfaces with tape. Failure to
do so may result in damage to unit or personal injury.
1. Remove the unit from the shipping carton and remove all
packing materials.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of the unit.
3. Carefully lay the unit on its side and install the four
Designer legs. Two people are required for this step.
At each corner on the bottom of the unit:
a. Thread a hex bolt through the short rubber foot (bolt
head on recessed side of foot), through the Designer leg
and into the corner hole on the base. Tighten securely.
Installing the 4" (102 mm) Designer Legs
4. After all the legs are secure, return the unit to its upright
position. Two people are required for this step.
5. Install the channel dividers and product divider bars.
a. Position the channel dividers onto the locator pins on
the front edge and back edge of the unit.
b. Place the product divider bars into the channel dividers.
The bars can be adjusted easily to separate holding
areas as needed.
Locator Pin
Installing Product Divider Bars
6. Install the glass side panels on each side of the unit. To
install the side panels:
a. Angle the top edge into the upper channel.
b. Carefully lower the bottom edge into the lower channel.
Do not allow the panel to drop into position.
Glass Side Panel
Lower Channel
Side Glass Panel Installation
7. Place the unit in the desired location. Two people are
required for this step.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F
(21°C). Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods,
air conditioning ducts, and exterior doors).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
8. For units without plugs, have a qualified electrician install
proper plug or hardwire to on-site power source.
12
English
Product Divider Rod
Channel Divider
Upper Channel
Form No. GR2SDM-0920

Publicité