General

Use the information in this section to prepare for and install
a Max Watt Strip Heater. Make sure to locate the specific
information in this section for the type of installation. Strip
heaters are shipped with most components pre-assembled.
Dual units are supplied with a required 3" (76 mm) or
6" (152 mm) spacer pre-assembled at the factory.
Optional mounting equipment and remote control enclosures
must be installed on location.
WARNING
FIRE HAZARD: Do not install Max Watt strip heaters
above or around combustible surfaces. Discoloration or
combustion could occur. Max Watt strip heaters must be
installed in non-combustible surroundings only.
CAUTION
To ensure safe and proper operation, refer to the "Minimum
Clearance Requirements" listed in the Installation section
of this manual.
NOTICE
Damage to any countertop material caused by heat
generated from Hatco equipment is not covered under
the Hatco warranty. Contact the manufacturer of the
countertop material for application information.
To prevent unit failure from excessive heat, do not add
a decorative soffit to hide a pass-through mounted strip
heater.
NOTE: Contact the countertop manufacturer of the base
material for application information and surface
temperature limits before installing the unit.
1. Remove the unit from the shipping carton and remove all
packing materials.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of the unit.
NOTE: If unit is equipped with optional equipment, see the
OPTIONS AND ACCESSORIES section near the back
of this manual.
3. Install/mount the unit in an appropriate location.
a. Verify recommended mounting heights and minimum
clearance requirements are met for the appropriate
model. Refer to "Recommended Mounting Heights" and
"Minimum Clearance Requirements" in this section.
b. For permanent unit installation, refer to "Installing
Permanent Units" in this section.
c. For chain suspension installation, refer to "Installing
Chain Suspended Units" in this section.
Form No. GRAMM-1220
Dual Mounting
When mounting units side-by-side, a space not less than 3"
(76 mm) must be maintained between units. Dual units ordered
from the factory are shipped with a pre-assembled 3" (76 mm)
or 6" (152 mm) spacer.
Installation of two or more separate units with less than
3" (76 mm) between housings may result in premature
failure of component parts. Failure to provide proper
spacing may result in heat damage to electrical
components and will void warranty.
Under Shelf Mounting
When mounting a unit under a shelf, use adjustable angle
brackets to assure proper spacing. Remote control enclosures
are required to keep switches out of the heat zone and prevent
premature failure.
Pass-Through
If pass-through area is 12" to 16" (305 to 406 mm) deep, a
single unit can be used. For a 20" to 24" (508 to 610 mm) deep
pass-through area, a dual unit is recommended. Installation of
multiple units must have a minimum spacing of 3" (76 mm)
between heaters.