IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be
implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions before
beginning installation and start-up. Therefore, the installer as well as the user must read the instructions before
beginning installation and start-up.
To achieve optimum performance of the Flat Floodlamp, follow the instructions indicated below:
1. VERIFY THE CONTENTS OF THE PACKING:
The following accessories are included inside the box:
Floodlamp unit
Crosshead mount
Bag of screws
Clamp (projectors: 24765; 33123; 35668; 43452; 43454)
2 adhesive joints (projectors: 24765; 33123; 35668; 43452; 43454)
Adhesive template (projectors: 24765; 33123; 35668; 43452; 43454)
Installation manual
2. GENERAL CHARACTERISTICS:
This floodlamp has been designed to be used fully submerged underwater in fresh water swimming pools. It is a Class III
electric apparatus with very low safety voltage (12V ~ with alternating current).
The floodlamp compiles with IPX8 degree of protection (resistance to penetration of dust, solid bodies and humidity) at a
nominal immersion depth of 2 m.
This floodlamp complies with international safety standards for lights, especially the EN 60598-2-18 standard: LIGHTS
PART 2: SPECIFIC REQUIREMENTS SECTION 18 LIGHTS FOR SWIMMING POOLS AND SIMILAR APPLICATIONS.
The mains supply to the light should have 30 mA overload protection. The electricity supply to these lights should be via an
independent isolating safety transformer with separated windings.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric components
which have been inserted or handled at locations other than its own premises.
3. INSTALLATION:
• In order to clearly light a pool it is recommended lo install a 100W floodlamp every 25m² or 35 m² of water surface. In
swimming pools which are especially deep, a 100 W floodlamp is required for every 30 or 40 m³ of water volume.
• In order to prevent glare, the floodlamps should be installed so that they face away from the residence or usual view of
the swimming pool.
• In the event that lighting is used in training or competition pools, the floodlamps should be installed on the sides to
prevent glare on the swimmers.
• To avoid the need to empty the pool to change the lamp, we recommend that the floodlamp be installed in areas which
are accessible from the upper edge of the pool.
Prior to installation verify that the gland seal has been fully tightened.
The floodlamp should be placed on the wall of the pool at approximately 700 mm from the water surface (Fig. 1).
The method of fastening the crosshead mount to the pool wall varies depending on whether it is a floodlamp for concrete
pools or prefabricated pools.
Concrete pool (MODEL 21626 - 35666) Page 14
Place the crosshead mount of the flat floodlamp (No. 24) in the designated place. Mark the holes. Drill with a 6 ∅ bit and
insert the 4 fastening blocks (No. 25).
Position the crosshead mount so that the word "TOP" is located on the upper part.
Use four 4.8 x 25 screws (No. 23) to secure the crosshead mount to the wall (Fig. 2).
Place the conduit body (No. 22) in the upper left quadrant of the crosshead mount, in accordance with the measurements
shown in Fig. 3.
Concrete pool with liner (MODEL 43452 – 43454) Fig. 11
Put the adhesive template on the concrete (No. 1) and drill in the designated points. Then, insert the fastening blocks
(No. 2).
Use the 4 4.8 x 25 screws (No. 3) to secure the clamp (No. 4), then stick one of the adhesive joints (No. 6) to the clamp
(No. 4).
Place the liner (No. 5) and stick the other adhesive joint (No. 6) to the liner. Remember to cut back the liner for the
housing of the cable duct hose.
Place the flat joint (No. 7) and screw in the cable duct body (No. 8) and finally screw on the mounting bracket (No. 9) with
the 4.8x25 screws (No. 3).