Picture 6 - Tolerance for flue outlet on the top and back. The tolerance depends on the orientation of the
connector.
The connection with the chimney must be always
well fixed and sealed, it must not have narrowing
and must not decrease the usable section of the
chimney (see picture 7). If near the thermal cooker
NO
Picture 7 - Samples of correct and incorrect connection to the chimney hood.
2.9
FLUE OUTLET ON THE SIDE (OPTIONAL – STP)
On demand, STP can have the flue outlet on the
right side. The connector is extractable. To install
it correctly, it is necessary to remove the cooking
plate. Now, the connector must be completely in-
serted inside the wood fired cooker or the chim-
ney, keeping the fixing buttonhole on the same
Picture 8 - Flue outlet on the side. Fixed connector for the flue outlet on the side.
Y
+/-
10 mm
there is inflammable material or high temperatures
sensible, the connection must be isolated and the
safety distances must be strictly observed.
NO
NO
side of the cooker. Then, you can place the wood
fired cooker, extract correctly the connector so
that it connect the cooker with the chimney. Final-
ly, bend the buttonhole and block the
parts with the screw-lock (see picture 8).