Télécharger Imprimer la page

krispol STARCUS K06 Manuel D'utilisation page 11

Masquer les pouces Voir aussi pour STARCUS K06:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
GB
Programming
1
Preparation
With the Carriage Release Lever horizontal, move the door by hand until the Carriage engages, with the
2
Shuttle.
3
Turn on the power, the Lamp comes on while the Display runs from '99' to '11'.
4
The Display changes to '--'. Standby Mode.
5
Setting Open and Close Positions
6
Press and hold the P button, until 'P1' is displayed.
Press P again, 'OP' is displayed.
7
8
Press and hold the ∆ button. While opening, 'OP' flashes.
9
Release the ∆ button when the open position is reached.
10
Use the ∆ or
buttons to adjust the open position.
Press P, and 'CL' is displayed.
11
12
Press and hold the
13
Use the ∆ or
buttons to adjust the closed position.
Press P, and the door will open and close automatically to establish normal force requirements. Finally '--'
14
is displayed.
15
Adding Remotes
16
Press the C button. 'Su' is displayed.
17
Choose and press a button on the Remote.
18
Press the same button again to confirm.'SU' flashes and then '--' is displayed.
Repeat the above steps for additional eKey Remotes. A maximum of 20 may be stored. An attempt to
19
add another will display 'Fu'.
20
Deleting Remotes
21
Caution: This function deletes all remotes
22
Press and hold the C button for 8 seconds. 'dL' is displayed
23
Operating Force Adjustment
24
Press and hold the P button, until 'P1' is displayed.
25
Press the ∆ button once. 'P2' is displayed.
Press P again. The current force setting is displayed. Press ∆ or
26
one step at a time. Maximum is 'F9'; Minimum is 'F1'. Press P to confirm.
27
Default setting is 'F3'
Safety Beam – Enabling and Disabling
28
29
Press and hold the P button, until 'P1' is displayed.
30
Press the ∆ button twice. 'P3' is displayed.
31
Press the P button to show the beam Status. 'H0' means Disabled, 'H1' means Enabled.
Press the ∆ button to Enable. 'H1' is displayed.
32
33
Press the
button to Disable. 'H0' is displayed.
34
Press the P button to confirm and exit.
NOTE: If Safety Beams are not fitted, ensure the above function is Disabled, or the operator will
35
open, but will not close.
36
Auto-close
37
Press and hold the P button, until 'P1' is displayed.
Press the ∆ button three times. 'P4' is displayed.
38
Press the P button to show the Auto-close Status. 'b0' means 'No Auto-close', 'b9' is maximum Auto-
39
close.
Press the ∆ button to increase, or the
40
41
Press the P button to confirm and exit.
Notes and Warnings:
Only operate the door when it is in full view.
Do not allow young children to play with the controls.
Keep people, pets and property clear of the moving door.
The door operator is intended for indoor installation.
The door and operator should be serviced annually
button. While closing, 'CL' flashes.
button to decrease the delay by 1 minute.
to increase or decrease this value by
99 - 11
––
P1
OP
OP
CL
CL
––
Su
SU
dL
P1
P2
F3
P1
P3
H0 - H1
H1
H0
P1
P4
b0 - b9
11

Publicité

loading

Ce manuel est également adapté pour:

Starcus k10