6
Troubleshooting
Problem
Possible causes
Pump does not prime
• Pump defective
• Flushing hose or dirt filter blocked
• Too much air inside the pump
In this case, the pump can be vented by means of the
screw at its front side (see fig.)
Pump does not build
• Pump defective
up pressure
• Pressure hose blocked
Pump cannot be
• Pump overheated (115 V~ version only)
switched on
The overheat protection (thermistor) has been
triggered. Wait until the pump has cooled down, then
push in the overheat protection.
overheat protection
(thermistor)
vent screw
7
Accessories and spare parts
When ordering spare parts, state the serial number of the SOL-CADDY.
1
Lid
Article no. 28005030
2
2 x Wheel incl. axle
Article no. 28004420
3
Fill / Drain valve
Article no. 28005040
Drain valve for the tank
4
Hose set
Article no. 28005010
including:
1 × flushing hose, 3,1 m
1 × pressure hose, 2,2 m
5
Ball valve set
Article no. 28005060
for pressure and flushing hose
6
Dirt filter
Article no. 28005050
7
Extension cable
Article no. 28005070
5 m, DE version
1
6
7
4
5
3
2
19