4. Technical data

Power supply:
Max. rated current consumption:
Max. compressor starting current:
Max. power consumption:
Sound pressure level:
Dehumidifying capacity:
0.41 l/h (at a room temperature of 30°C and air
0.18 l/h (at a room temperature of 27°C and air
Operating range for humidity
Operating range for temperature:
Max. air flow volume:
Volume of condensate container:
Coolant:
Refrigerant group:
Coolant quantity:
Appliance dimensions:
Appliance weight:

5. Before using

If the switch is "ON", the dehumidifier is running
continuously.
The unit switches off automatically as soon as the
condensate collector is full.
Constant condensate drainage can be set.
Operating principle
The humid air condenses on the cooler elements and
is transferred to the water tank. The dry air is heated
a little on the condenser and returned to the room. A
refrigerant compressor is needed for operation.
Notes:
The room temperature should lie in the range
from 8 to 32°C. The dehumidifier will not work
effectively outside this range.
To achieve an optimum circulation of air it is
recommended that the appliance be set up in the
middle of the room as far as possible.
Avoid open windows and doors and entering and
leaving the room frequently, etc.
The appliance must never be used in excessively
dusty rooms or rooms with excessive amounts of
chlorine.
19.01.2011
8:46 Uhr
Seite 11
The dehumidifying performance of the appliance
is dependent on the characteristics of the room,
the room temperature and the relative humidity.
220 - 240V ~ 50 Hz
If the condensate container is not fitted correctly,
1.2 A
the appliance will not work.
3.4 A
To prevent high starting currents the appliance is
equipped with a restart inhibit which only restarts
260 W
the compressor after a delay of 3 minutes.
≤ 45 dB(A)
The appliance can be installed on a flat, stable
surface, free-standing anywhere in the room.
Observe the minimum separation distances.
humidity of 80%)

6. Using for the first time

humidity of 60%)
40-90%
To switch on/off (Fig. 1)
8 -32°C
Check that the voltage from the mains power supply
is the same as the voltage indicated on the rating
100 m
3
plate. Connect the plug to the 230 V ~ 50 Hz power
2.0 liters
socket.
R134a
To switch the appliance on, turn the switch (2) to
L1
"ON". To switch off, turn the switch to "OFF".
90 g
500 x 280 x 145 mm
6.1.1 Operation with condensate collector
Take care during operation of the condensate
7.5 kg
collector (5) that the rubber stops on the underside of
the appliance are firmly attached to the drainage for
the hose connection. Otherwise there may be water
loss on the underside of the appliance (Water
damage).
Emptying the Condensate collector (5)
If the condensate collector is full, the appliance
switches itself off automatically and the LED
indicating "Condensate reservoir full" (3) lights up.
Remove the condensate collector by pulling it
sideways out of the housing, then empty it. After
emptying the collector, insert this again in the correct
position
Note:
If the tank is not inserted correctly the "Condensed
water tank full" LED will continue to shine.
6.1.2 Operation with water drainage hose
(Fig. 2 – 4)
1. Press the fastening clamp (A) together and cover
with a fitted water drainage hose of interior
diameter 10mm. The fastening clamp is designed
for hoses with an external diameter of approx.
13mm. For other hoses, please use an
appropriate hose clamp.
2. Insert the pressure spring (B) with the narrower
end into the hose.