Setting The Temperature Control - Wilo Star-Z NOVA Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
65 °C
no °C
AA1
Installation and operating instructions Wilo-Star-Z NOVA T
NOTICE: If the pump is running during a
switch-on time, "1/on", "2/on" or "3/on" is
shown in the display.
During the switch-off time, "off" is shown in the
display.

6.3 Setting the temperature control

1.
5 sec.
2. Select temperature control
(flashes).
3. Set the temperature.
Setting range = 40 – 70 °C.
Means that the temperature
control is switched off.
The pump runs on, independent
of the return temperature.
Warns about a non DVGW-compliant setting and
appears when the temperature is below 55 °C.
4. Switching thermal disinfection
on/off.
5. Select the standard display.
Settings
+
5 sec.
+
+
+
21