Selecting The Operating Mode - Thitronik Pro-finder Instructions De Service Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pro-finder Manual
1.3 Connections, displays and control elements
Connection – external GPS receiver (option)
Operating mode switch

1.4 Selecting the operating mode

In all modes the outputs can be switched as described under 2.7. The following
functions can be activated by setting the operating mode switch (see 1.3):
Call triggers status report:
If you call the phone number of the SIM card inserted in Pro-finder,
Pro-finder automatically ends the call and sends a status report (see 2.1, Fig. 1)
to the caller (authorised numbers only) (see 2.1).
Automatic status reports:
Pro-finder sends status reports to the saved destination phone numbers
at the intervals listed below.
Status report contains U1, U2, U3, U4, U5:
The status report contains additional information on the operating voltage (U1)
and the voltages on the measurement inputs U2-U5. The voltages displayed
vary with the position of the switch.
Geofencing switchable via pin 3:
If the voltages cited in the table are applied on pin 3, geofencing can be
switched on and off controlled by event. For example, by switching on the
ignition or activating the interior light, etc.
Not used
Connection WiPro III / "all in one"
Pin 5 measurement input (U5)
Pin 6 output B
Pin 7 output A
Pin 8 operating voltage (U1)
+12 V
Pin 1 ground (GND)
Pin 2 measurement input (U2)
Pin 3 measurement input (U3)
Pin 4 measurement input (U4)
Page 2