DESCRIPTION
1
SANICOMPACT
Comfort/SANICERAMIC 4
®
is a wall hung WC pan fitted with a pump
macerator.
The SANICOMPACT
Comfort/
®
SANICERAMIC 4
can only be installed with
®
the special support brackets supplied.
SANICOMPACT
Comfort/SANICERAMIC 4
®
is for use in a domestic environment.
Installed and used correctly, SANICOMPACT
Comfort/SANICERAMIC 4
will give reliable
®
and consistent service.
Please note the following warning signs:
"
" Possible danger to personnel,
"
" Warning of possible electrical hazards,
"WARNING" This is a general warning that
failure to follow instructions could result in
poor functioning of the unit.
PRINCIPLES OF OPERATION
SANICOMPACT
Comfort/SANICERAMIC 4
®
is controlled by an electronic timer.
It macerates and pumps away waste:
The unit is operated by pressing one of the
two options of the grey pushbutton built into
the bowl (light grey: short flush, dark grey: full
flush).
LIST OF ACCESSORIES SUPPLIED
2
DIMENSIONS
3
TECHNICAL DATA
4
Applications
WC discharge
Type
Maximum Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption 2,5 A
Medium water temperature
Electric Class
Degree of protection
Net Weight (with frame)
WARNING:
Only installations conforming to
the above specifications are acceptable.
PERFORMANCE CURVE
5
VERTICAL/HORIZONTAL
6
PUMPING COMBINATIONS
INSTALLATION
7
PREPARATIONS
NB:
before installing your SANICOMPACT
Comfort/SANICERAMIC 4
, make sure that
®
the wall which is to bear the load is strong
enough to support the appliance. (Max shear
force per fixing: 120kg).
7a
FIXING THE BOWL ONTO THE
SUPPORTING UNIT
1
- Secure the M12 rods
fixing holes so the following length
protrudes:
L = 45 mm + X (X = thickness of any
covering panel, plasterboard or tiling).
®
2
- Position the plastic inserts
holes of the bowl.
NB:
make sure the side opening in the
insert is in line with the side opening in
the bowl
®
®
7b
ADJUSTING THE HEIGHT OF THE UNIT
1
- Attach the feet
and screw into the frame.
2 -
Offer the support unit up to the wall.
3
- Adjust the height of the bowl above
the floor: for a seat height of 430mm
(standard height), adjust the rods
to protrude by 65mm.
Check that the unit is horizontal.
®
7c
FIXING THE UNIT TO THE WALL
1 -
Offer the unit up to the wall.
2 -
Check that the unit fits flush to the wall.
3
- Mark the unit fixing points (2 holes in the
upper part of the unit and 2 holes in the
lower part).
4
-
if your wall is not perfectly vertical,
NB:
use the four holes provided on the unit to
make good any gap between it and the
wall by adding washers.
These gaps are filled by adding flat washers –
not supplied – between the wall and the unit.
5 -
Choose wall fixings suitable for the wall
material (use 8mm x 120 mm or larger –
not supplied).
6
- Drill holes in the wall using a suitable
CR15 DF
size of bit – not supplied – for the
3 m
chosen fixing.
220-240 V
7
- Fix the unit to the wall.
50 Hz
550 W
8
-
NB:
The distance between the wall and the
35°C
front of the covering panel must not
I
exceed 100mm.
IP44
The covering panel must always be right up
32 Kg
against the unit.
7d
WATER SUPPLY
1 -
Run the water supply with copper pipe
in 15 mm, fitted with a 22 mm male iron
to connect to the SANICOMPACT
Comfort/SANICERAMIC 4
2 -
The water supply pipe must be fitted in
the upper part of the frame.
3 -
WARNING:
isolation valve when fitting the pan.
4 -
For correct rinsing of the bowl, the water
®
pressure entering the pan must be
minimum 1,7 bar.
A
in the frame's
D
in the
B
to the M10 rods
A
A
®
.
®
It is essential to install an
8
7e
DISCHARGE CONNECTION
1 -
The discharge pipe should be either
copper or UPVC solvent weld pipe with
32 mm diameter.
2 -
Put the end of the pipe through the
upper part of the frame.
If the discharge pipework runs to a level
3 -
considerably lower than SANICOMPACT
Comfort/SANICERAMIC 4
resultant syphoning effect can suck out the
water seal in the unit. Fitting an air admit-
tance valve (BBA approved) at the high
point of the pipe run will overcome this pro-
blem.
7f ELECTRIC POWER SUPPLY
7f
The electrical installation work must be
carried out by a qualified person.
The electrical installation work for the
equipment, in a bathroom, must be carried
out in accordance with the standards in force
in the country (NF C 15-100 in France).
The electric power supply as wired
beforehand by the installer must be class 1,
using 3 X 0.75 sq. mm wiring.
1 – Connect the electric power supply to a
triple screw connector (not supplied) in
an
IP55 junction box (Sarel 01650 or
similar) installed beforehand, complying
with the following colours:
Brown = phase
Blue = neutral
Green/Yellow = earth.
2 – This connection must be used solely to
power the equipment, and it must be
protected by a high sensitivity 30mA
differential circuit breaker, set at 16 A.
3 -
ATTENTION:
the electrical junction box
must remain accessible after installation
of the toilet.
MOUNTING THE PAN AND
8
CUTTING OUT THE FASCIA
PANEL
1 -
Offer up the fascia panel (not provided) to
the support frame which has been fixed to
the wall.
2 -
Locate the panel exactly to the support
frame.
3
- Drill 2 holes (25mm) through the fascia
panel to correspond with the threaded rods
on which the pan will hang.
4
- Offer up the template
to the support wall
C
fascia, positioning the holes for the WC
support rods accordingly.
5 -
Trace the inner shape of the template onto
the fascia.
6
- Remove the template
and cut out the
C
fascia as traced.
7
- Make any finishes to the support wall and
fix on the fascia panel.
8 -
Note:
If you are tiling the wall, the tiles will
have to be cut out in the same way as the
fascia panel.
®
unit, the
®

Publicité

loading

Ce manuel est également adapté pour:

Sani ceramic 4