Installation Position; Installing The Filter - Judo EASY FILT-B JEF-B Instructions De Montage Et De Service

Filtre de protection à rétrolavage 3/4" - 1 1/4"
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.1.2 Installation position

ATTENTION
(see
chapter
"Safety
dangers due to non-compliance")
Always install the filter in a vertical position
(± 5°)!
Failure to observe this can cause uncon-
trolled backwashing water to escape and
can result in damage caused by water.
4.1.3 Mounting the built-in rotary
flange
Install using the supplied built-in rotary
flange. The built-in rotary flange is used as a
connecting element between the pipe and
the filter.
It is suitable for both horizontal and vertical
pipes.
The built-in rotary flange must be
installed in the direction of flow. This is
marked by a cast in arrow.
Failure to comply with this means the filter
cannot work.
ATTENTION
(see
chapter
"Safety
dangers due to non-compliance")
The flange surface of the built-in rotary
flange must be in a horizontal position! The
built-in rotary flange must be fitted so that
mechanical stresses cannot occur! Other-
wise mechanical damage can result in the
built-in rotary flange. Otherwise mechanical
damage can result, the pipe may burst or the
built-in rotary flange can break. This can
result in major water damage.
In this case, people close to the filter are
exposed to a health risk due to the large
quantities of water.
8
Installation
information
and
information
and
JUDO EASY FILT- B
Therefore, during installation, ensure that no
large forces act on the pipe, built-in rotary
flange and filter.

4.1.4 Installing the filter

Select the torque (approx. 4 Nm) so
that the gasket closes and the filter
is not damaged or strained!
The filter is connected using the supplied
built-in rotary flange. It consists of the built-
in rotary flange, the profiled flange seal,
union nuts, sleeves and flat seals.
– Undo the built-in rotary flange union nuts
and fit to the pipe with the sleeve.
– Note the installed dimensions!
– Position the filter with pre-fitted built-in
rotary flange between the sleeves, insert
the flat seals and screw using the union
nut.
The cast in arrow of the built-in rotary flange
must match the direction of flow of the water
(see fig. 1).
ATTENTION
(see
chapter
"Safety
dangers due to non-compliance")
profiled flange gasket
Fig. 3: Profiled flange gasket
The section of the profiled flange gasket
must point towards the built-in rotary flange
(see fig. 3). Failure to observe this can lead
to leaks and water escaping. This can in turn
cause water damage to the house and its
installations.
information
and

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

807064680706478070648

Table des Matières