4.

Installation

4.1

General

ATTENTION
(see
chapter
"Safety
dangers due to non-compliance")
The unit may only be installed by skilled
personnel.
The chapter "Intended use" must always be
observed!
The pipes must be able to safely support the
filter.
Otherwise mechanical damage or fractures/
bursts can occur in the pipes. This can result
in major water damage. People close to the
filter are exposed to a health risk due to the
large quantities of water released. There-
fore, if necessary, the pipes must be addi-
tionally fixed or supported.
A space of at least 200 mm should be main-
tained above and below the filter. These
distances are necessary to be able to prop-
erly carry out the backwashing (see chapter
"Discharging the backwashing water").
Installation
information
and
JUDO EASY FILT- B
4.1.1 Requirements for the place of
installation
The room where the unit is installed must
be dry and frost free!
Unauthorised persons must not have
access to the filter!
ATTENTION
(see
chapter
"Safety
dangers due to non-compliance")
– The ambient temperature must not
exceed 30 °C (86 °F)! At higher tempe-
ratures or direct sun radiation the mate-
rial can be damaged and the filter cover
can even break.
– In order to be able to safely discharge
the wastewater in operation and in case
of any defects that occur in the system,
precise compliance with the details
given in the "Installation" chapter is
necessary!
If the wastewater (backwashing) cannot
be safely and completely discharged,
the house and installations can be
damaged by water.
– A shut-off valve must be installed
upstream of the filter! This enables the
water supply to the filter to be interrupted
during
installation,
nance, repairs and in case of malfunc-
tions. Floods and serious water damage
to house installations can therefore be
avoided.
– The unit can be installed in all standard
drinking water pipes.
– It is not permitted to install the filter
upstream of the water meter!
information
and
servicing/mainte-
7

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

807064680706478070648

Table des Matières