Safety Notes; Installation Instructions; Symbol Description; Flow Diagram - Hansgrohe Focus 100 31509000 Mode D'emploi / Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
• The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
Technical Data
This mixer series-produced with
EcoSmart® (flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
4
English
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 32

Symbol description

Adjustment (see page 35)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Do not use silicone containing acetic acid!
Dimensions (see page 31)

Flow diagram

(see page 32)
with EcoSmart
without EcoSmart
Spare parts (see page 37)
Special accessories (order as an
extra)
special tool #58085000
seal #98996000
Installation putty
Operation ( see page 36)
• Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
• After periods of prolonged non-use, but
at least every third day, the fittings must
be opened with the handle in hot and
cold position to prevent stagnation in the
connecting lines. Let the water run until the
water temperature is constant.
Cleaning (see enclosed brochure)
Test certificate (see page 40)
®
®

Publicité

Table des Matières
loading

Table des Matières