Installation Clearances; Location Requirements - Whirlpool WET3300S Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the washer/
dryer. See "Electrical Requirements."
A sturdy floor to support the washer/dryer weight (washer/
dryer, water, and load) of 500 lbs (226.8 kg).
A level floor with a maximum slope of 1" (25 mm) under entire
washer/dryer. Clothes may not tumble properly and automatic
sensor cycles may not operate correctly if washer/dryer is not
level. Installing on carpet is not recommended.
A water heater set to deliver 120°F (49°C) water to the washer.
Hot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water fill valves, and water pressure of 5-100 psi
(34.5-689.6 kPa).
The washer/dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
Do not operate your washer in temperatures at or below 32ºF
(0ºC). Some water can remain in the washer and can cause
damage in low temperatures. See "Washer/Dryer Care" in the
Washer/Dryer User Instructions for winterizing information.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit,
installation of the washer/dryer in garages, closets, mobile homes,
or sleeping quarters. Contact your local building inspector.

Installation Clearances

The location must be large enough to allow the dryer door to open
fully.

Location Requirements

Washer/Dryer Dimensions
*Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
washer/dryer. This washer/dryer has been tested for spacing of 0"
(0 mm) clearance on the sides. Recommended spacing should be
considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door,
and floor moldings.
Additional spacing on all sides of the washer/dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
27"
1"
(25 mm)
(686 mm)
A
*Required spacing
**Rear clearance may be 1" (25 mm) when house exhaust system
is lined up directly with dryer exhaust.
Mobile Home - Additional Installation Requirements
This washer/dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280) or the Canadian Manufactured
Home Standard, CAN/CSA-Z240 MH.
71 "
5
8
(1819 mm)
(603 mm)
*32"
(813 mm)
27"
(686 mm)
6"
(152 mm)
(310 cm
(155 cm
1"
5"**
1"*
32"
(25 mm)
(25 mm)
(127 mm)
(813 mm)
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
23 "
3
4
32 "
1
4
(819 mm)
3"
(76 mm)
48 in.
2
)
2
24 in.
2
3"
)
2
(76 mm)
C
3