Hatco 3CS Série Manuel D'installation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
3. Remove the template and cut a 2" (51 mm) diameter hole
at each pilot hole location using a knockout hole punch.
4. Make a 1/8" (3 mm) offset around each 2" (51 mm) diameter
hole. The offset should be a diameter of 3" (76 mm)
centered around the hole.
(76 mm)
Dia. Offset
(51 mm)
Dia. Hole
Sink or Tank
Bottom
Side View of Hole and Offset
Installing the Drain Spud Assembly
5. Unscrew the drain spud assembly from the welded pipe on
the heater.
3"
1/8"
2"
(3 mm)
Offset
Height
Drain Spud
Thin Rubber
Thin Rubber
Washer
Washer
Sink/
Vessel
Bottom
Two Thick
Rubber Washers
Fiber Washer
Locknut
Union Washer
Union Nut
6. Unscrew the locknut from the drain spud assembly and slide
off all of the washers except the thin rubber washer.
7. With only the thin rubber washer attached to the drain spud,
slide the drain spud through the sink hole from above.
8. Secure the drain spud assembly to the sink or holding
vessel.
a. From under the sink, slide the two thick rubber washers
followed by the fiber washer onto the drain spud.
b. Screw the locknut (flat side up) onto the drain spud.
9. Repeat steps 5–8 for the other spud assembly.
10. Secure the unit to the sink or holding vessel. Two people
may be required for this step.
a. Position the unit under the two spud assemblies.
NOTE: Make sure the union washers are positioned properly
inside the union nuts and are not crimped.
b. Screw the union nut to the threaded drain spud assembly.
Do not use excessive force when tightening unions or nuts.
Over-tightening and excessive force may cause leaks.
11. Tighten the union nuts and locknuts securely.
12. Verify drain valve handle is in closed (vertical) position.
13. Fill the sink or holding vessel with water and check for leaks.
NOTE: A 3/4" (19 mm) hose or pipe may be connected to the
sump drain and run to an open sight drain. The sump
drain should not be permanently connected to the
sanitary drain system. Check local plumbing code for
proper drain installation. See the MAINTENANCE
section for more information.