Con-
Description
Range
tents
Boost level/Max. power limit
in DHW
0-100%
(b02=1)
Not implemented (b02=2)
b07
Boost level/Max. power limit
in DHW
0-100%
(b02=3)
Not implemented (b02=4)
Boost Timer/Max. power limit
in DHW
0-255%
(b02=1)
Not implemented (b02=2)
b08
Boost Timer/Max. power limit
in DHW
0-255%
(b02=3)
Not implemented (b02=4)
b09
Fan min. frequency Offset
0-220Hz
(b02=1)
Fan min. frequency Offset
0-220Hz
(b02=2)
Fan min. frequency Offset
0-220Hz
(b02=3)
Fan min. frequency Offset
0-220Hz
(b02=4)
b10
Summer/Winter button opera-
0=Enabled
tion selection
1=Disabled
b11
Variable input contact opera-
0=Flowmeter
tion selection (b02=1)
exclusion
1=System ther-
mostat
2=Second room
therm.
Variable input contact opera-
0=Economy/
tion selection (b02=2)
Comfort
1=Continuous
Comfort
2=Second room
therm.
Variable input contact opera-
0=Flowmeter
tion selection (b02=3)
exclusion
1=System ther-
mostat
2=Second room
therm.
Variable input contact opera-
0=Economy/
tion selection (b02=4)
Comfort
1=Continuous
Comfort
2=Second room
therm.
b12
Not implemented (b02=4)
b13
Relay card LC32 operation
0=External gas
selection (b02=1)
valve
1=Alarm
2=System filling
solenoid valve
3=Solar 3-way
valve
4=Second heat-
ing pump
5=Alarm2
Relay card LC32 operation
0=External gas
selection (b02=2)
valve
1=Alarm
2=System filling
solenoid valve
3=Pump for
Legionella pro-
tection
4=Second heat-
ing pump
5=Alarm2
Relay card LC32 operation
0=External gas
selection (b02=3)
valve
1=Alarm
2=System filling
solenoid valve
3=Solar 3-way
valve
4=Second heat-
ing pump
5=Alarm2
No effect on adjustment
(b02=4)
24
EN
Default
SILVER 24T
100%
--
--
--
100%
--
--
60seconds
--
--
--
60seconds
--
--
10Hz
10Hz
10Hz
10Hz
10Hz
0=Enabled
0=Enabled
0=Flowmeter
exclusion
0=Economy/Com-
0=Economy/
fort
Comfort
0=Flowmeter
exclusion
0=Economy/Com-
fort
--
--
--
0=External gas
valve
0=External gas
0=External gas
valve
valve
0=External gas
valve
--
--
cod. 3541I691 - Rev. 00 - 01/2017
Con-
Description
SILVER 34T
tents
b14
Hours without DHW drawn
(b02=1)
No effect on adjustment
--
(b02=2)
Hours without DHW drawn
(b02=3)
No effect on adjustment
(b02=4)
b15
Fault 20Selection status
b16
Fumes Max Temperature
--
b17
Mains Voltage Frequency
b18
Comfort burner on time
(b02=1)
Not implemented (b02=2)
Not implemented (b02=3)
Not implemented (b02=4)
10Hz
b19
Flowmeter timing (b02=1)
No effect on adjustment
(b02=2)
Flowmeter timing (b02=3)
0=Enabled
No effect on adjustment
(b02=4)
b20
Fan type selection
b21
Pump antiblock operation
time
0=Economy/
Comfort
b22
Hydraulic unit configuration
b23
DHW demand type selection 0=Flowmeter
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting
occurs automatically after 2 minutes.
Service menu
The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 sub-
menus are available: press the Heating buttons to select, in increasing or decreasing or-
--
der, "tS", "In", "Hi" or "rE". "tS" means Transparent Parameters Menu, "In" means
Information Menu, "Hi" means History Menu: after selecting the submenu, press the Re-
set button again to access it; "rE" means History Menu Reset: see description.
"tS" - Transparent Parameters Menu
31 parameters are available, indicated by the letter "P", which are not modifiable from
Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
0=External gas
Con-
valve
Description
tents
Ignition Power
(b02=1)
Ignition Power
(b02=2)
P01
Ignition Power
(b02=3)
Ignition Power
(b02=4)
P02
Heating ramp
No effect on adjust-
ment (b02=1)
No effect on adjust-
ment (b02=2)
P03
No effect on adjust-
ment (b02=3)
No effect on adjust-
ment (b02=4)
Heating standby
P04
time
SILVER 24T - 34T
Range
Default
0-24hours
24hours
0-24hours
24hours
0-24hours
24hours
24hours
0=Disabled
0=Disabled
1=Enabled
0-125°C
100°C
0=50Hz
0=50Hz
1=60Hz
0-40seconds
15seconds
--
--
--
--
--
--
0=Disabled
0=Disabled
1-10=seconds
0=Disabled
0=Disabled
1-10=seconds
0=Disabled
0=Disabled
1-10=seconds
0=Disabled
0=Disabled
1-10=seconds
0=Sit
2=Ebm NRG77
1=Ebm NRG118
2=Ebm NRG77
0-20seconds
5seconds
0=Stepper motor
0=Stepper motor
valve
valve
1=230Vac valve
0=Flowmeter (450
(450 imp/l)
imp/l)
1=Flowmeter
(700 imp/l)
Range
Default
SILVER 24T
0-100%
40%
0-100%
40%
30%
0-100%
40%
0-100%
40%
2°C/
1-10°C/minute
2°C/minute
minute
20-80°C
35°C
20-80°C
35°C
35°C
20-80°C
35°C
20-80°C
35°C
0-10minutes
4minutes
4minutes
SILVER 24T
SILVER 34T
24hours
24hours
0=Disabled
0=Disabled
100°C
100°C
0=50Hz
0=50Hz
--
--
0=Disabled
0=Disabled
2=Ebm NRG77
2=Ebm NRG77
5seconds
5seconds
0=Stepper motor
0=Stepper motor
valve
valve
0=Flowmeter
0=Flowmeter
(450 imp/l)
(450 imp/l)
SILVER 34T
30%
2°C/minute
35°C
4minutes