Operating mode B:
When the device is turned on, target values for speed and time setting
are adopted before the device is turned off (power OFF). The upper
speed limit that has been set is taken over from operating mode A
when this operating mode is selected and cannot be modified.
When you turn on the device with the power switch, a B is shown on
the display for operating mode B along with * in the right display.
After the power has been turned off,the device will no longer auto-
matically start up in operating mode B by itself.
After you have selected operating the mode and turned on the device,
the following process will be shown on the display.
a.) All display elements in the digital displays are activated for about 2
seconds.
b.) The device type (left display) and operating mode (right display)
displayed for about 2 seconds.
I 3 0
K S
c.) After this, the set (or stored) upper speed limit of the agitator is
shown in the left display with SAFE and OK for about 2 seconds. As
long as the upper speed limit is being displayed, it is not possible ti
change the upper speed limit.
The stored time target value or the one that has just been set (for
24
3 5 6 .
3 5 8 :
example 3:58) is shown in the right display with the indication h min
and a flashing SV . The user can recognize that operating mode B is
i
active by the star * in the display for the time setting.
n
m i n
PV
d.) The new speed target value has been set or just stored in the left
display (for example 130) is the shown in the unit 1/min and flashing
SV .
e.) By pressing the left or right turn button, you can place the agitator
in operation with the stored value or the one that has just been set.
The speed and time values are then shown in large format on the
display. In addition, the text PV is shown on the display instead of
SV . The actual value of the time setting must be understood from this
point onward as the time remaining for the agitation process. If the
time remaining has reached zero, the agitator stops its motion.
B
,
Operating mode C:
The upper speed limit that has been sett is taken over from operating
mode A when this operating mode is selected and cannot be modi-
fied. The target values from operating mode A or B are adopted for
speed and time and cannot be modified. When you turn on the device
with the power switch, a C is shown on the display for operating mode
C along with * in the display.
2 3 0
S A F E
O K
I 3 0
I
/
m i n
SV
I 3 0
3 5 6 .
I 3 0
I
/
m i n
PV
3 5 8 :
i
n
m i n
SV
,
3 5 8 :
i
n
m i n
SV
,
3 5 8 :
i
n
m i n
PV
,