Leak Testing - 3 Embers GAS9675AF Notice D'utilisation

Table des Matières

Publicité

HOSE AND REGULATOR:
Your grill is equipped with a Type 1 connection device with the following features:
1 . The system will not allow gas flow from cylinder until a positive connection to valve has been made .
Note: The cylinder valve and all grill burner knobs must be turned OFF before any connection is made or
removed .
2 . A regulator flow limiting device, when activated, restricts the flow of gas to 10 cubic feet per hour . If the
flow limiting device is activated, perform Regulator Resetting Procedure .
Note: If your grill will not get hot enough to cook, the flow limiting device may have been activated .
CONNECTING HOSE AND REGULATOR:
1 . Inspect propane tank valve rubber seal for cracks, wear or deterioration
prior to use . A damaged rubber seal can cause a gas leak, possibly
resulting in an explosion, fire or severe bodily harm . Do not use a
propane tank with a damaged rubber seal .
2 . Attach or detach regulator to the LP gas cylinder only when cylinder is
at rest in tank holder .
3 . Check that the cylinder valve is closed by turning knob clockwise .
4 . Check that the grill's burner control knobs are "OFF" .
5 . Visually inspect hose prior to each use for damage, excess wear, or
deterioration . If found, replace hose before using your grill . Only the
manufacturer's supplied replacement should be used .
6 . Remove the protective plastic cap from cylinder valve .
7 . Check that the hose does not contain kinks, does not contact sharp edges, and does not contact
surfaces that may become hot during use .
8 . Hold regulator and insert the brass nipple into LP cylinder valve outlet . Ensure that the device is
centered properly .
9 . Turn large coupling nut clockwise by hand and tighten to a full stop . Take care not to cross thread
coupling nut onto cylinder valve . Do not use tools to tighten connection .
Note: If you are unable to make connection, repeat Steps 7 and 8 .
10 . Leak check all fittings before lighting your grill . See section on "Leak Testing" in this manual .
Note: To remove regulator from propane tank, turn off tank valve and rotate large coupling nut
counter-clockwise and remove .
REGULATOR RESETTING PROCEDURE:
If your grill will not get hot enough to cook, the flow limiting device may have been activated .
Mini Reset:
Turn ALL burner control knobs to "OFF" , turn off cylinder valve . Wait one minute . Slowly turn cylinder
valve ON and relight grill . If burner flame is higher and grill heats up properly – proceed with cooking .
Full Reset:
Turn ALL burner control knobs to "OFF" , turn off cylinder valve . Disconnect hose and regulator from cylinder .
Wait two minutes, reattach hose and regulator and perform leak test .
Never use your grill without leak testing all gas connections, hoses and propane tank. Follow
the section on "Leak Testing" in this manual for proper procedures.
7

LEAK TESTING:

WARNING
Inspect Rubber Seal (see page 6)