LOCATION REQUIREMENTS

Place the air conditioner on a flat level surface in a
location that is at least 51 cm from any wall.
NOTE: A minimum clearance of 51 cm from the air
conditioner to the wall must be maintained to ensure
proper airflow
Maintain a minimum 51 cm clearance around the air
conditioner to not block airflow
Keep the air conditioner free of any obstructions such as
drapes, curtains, blinds, etc.
The exhaust hose should be free of any obstructions.
Do not place the air conditioner on an unstable or raised
surface because it could fall and cause damage or injury.
Do not place the air conditioner in direct sunlight or near
a heat source such as baseboard heaters, stoves, etc.
The window panel can be installed in a window with a
90 cm to a maximum 130cm opening.
Screw (2)
1 for extension panels
1 for nozzle
Remote Control for
Cooling&Heating
Model
4

ELECTRICAL REQUIREMENTS

WARNING
Electrical Shock Hazard
Plug into a grounded outlet only.
Do not remove the ground contacts from the power
cord plug.
Do not use an adapter.
Do not use an extension cord.
o follow these instructions can result in death,
fire
shock.
POWER SUPPLY CORD
Wiring Requirements
230 Volt, 50Hz, 16-amp fused grounded outlet
The use of a time-delay fuse or time-delay circuit breaker
is recommended.
Use a dedicated circuit only.
NOTE: Do not operate any other electrical
appliances on this circuit or you may trip the circuit
breaker/fuse.
If this power supply cord is damaged, it cannot be repaired. It
must be replaced with a cord from the product manufacturer.