Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Reverse Osmosis System Assembly and Storage Tank Installation
1. Hold the Reverse Osmosis assembly up to the wall surface where you will install it. Mark locations
for the hanger washers and screws.
2. Fasten the hanger washers to the wall surface. Wood screws are included for fastening to a wood
surface. Provide other screws as needed.
3. Hang the Reverse Osmosis assembly on the hanger washers.
4. Connect the tubing to the storage tank: Run the length of 3/8" tubing (marked "STORAGE TANK")
from the tee fitting on the Reverse Osmosis module to the tank shutoff valve. Use Teflon Tape
prevent leaks.
Fig. 6A.
Storage tank
Fig. 6B.
*For drain line options see Filtration Drain Connection Installations section.
2" minimum clearance for
changing cartridges
Storage tank
Cold
water
supply
Hanger
washer
(2)
Screw
(2)
RO faucet
Sink
p-trap
Reverse Osmosis
system
TM
to
17

Publicité

Table des Matières
loading

Table des Matières