IRM – Infrared heaters
1. Notes for the user
NOTE
Dear customer,
Keep these instructions in a safe place and pass them
on to possible future owners.
ATTENTION!
This device can be used by children aged 8
and over and by persons with limited physi-
cal, sensory or mental aptitude or lack of ex-
perience and/or knowledge, providing they
are supervised or have been instructed in the
safe use of the device and understand the
associated potential dangers. Children must
not play with the unit. Cleaning and mainte-
nance may not be carried out by children
without supervision!
ATTENTION!
Children of less than 3 years should be kept
away unless continuously supervised! Chil-
dren between the ages of 3 and 8 may
switch the device on and off if they are su-
pervised or have been instructed in the safe
use of the device and have understood the
resulting dangers, providing that the device
is positioned or installed in its normal place
of use!
ATTENTION!
Children between the ages of 3 and 8 may
not switch on the device, clean the device or
carry out maintenance!
ATTENTION!
To avoid overheating, do not cover the heat-
ing device.
ATTENTION!
Some parts of the device can get very hot
and cause burns. Particular caution must be
taken with children or vulnerable people!
ATTENTION!
Install the device in such a manner that it
cannot be touched by a person in the bath-
tub or under the shower.
ATTENTION!
If the power cable is damaged, it must be re-
placed by the manufacturer so as to elimi-
nate potential dangers.
www.dimplex.eu
2. Assembly
ATTENTION!
The original brackets provided must be used.
These devices can be mounted vertically or horizon-
tally onto the wall or the ceiling.
They must be mounted so that flammable objects can
not be ignited.
When installing the heating device with mains power
socket and room thermostat, the protection zone in
accordance with VDE 100-701 must be observed.
Drilling dimensions, power cable
C
A
View of the front
Dimen-
sion
Model
A
mm
IRM 320W
620
IRM 650W
1220
IRM 800W
1520
IRM 1000W
1520
ATTENTION!
Do not install the device directly below a wall
socket.
2111/B
A
A
A B
A C
D E
Dimen-
Dimen-
Dimen-
sion
sion
sion
B
C
D
mm
mm
mm
440
-
440
1040
520
440
1340
670
440
1340
670
600
English
Dimen-
sion
E
mm
620
620
620
770
EN-2