2. Check the scope of delivery

1

3. Preparation

• Disconnect the battery and any external
electricity source.
2
3
4. Roof cut-out
424
+1
0
+1
400
0
Ausschnitt
12-
5. Forced venting
Figure
2: If the forced venting is to be dis-
rupted, you must insert the 4 slide-in ele-
ments into the underside of the frame as
shown in the picture, before installing the
1:5
roof window.
The overall required ven-
CAUTION!!!
tilation cross section of
the vehicle has to be adhered. In doubt, the
required cross section should be verified with
2
3
the vehicle manufacturer.
6. Attach the seal
Insert the sealing cord into the intended
groove all around the outer frame, and over-
lap the ends by at least 50 mm. Make sure
4
5
12,5 mm
Dateiname des Zeichnungsobjektes:
AUSSCHNITT_VISTA
REMIS
Math.-Brüggen-Str.67-69
50829 Köln
Tel: 0221/78880-0 Fax:-249
Zust.
Änderung
Datum Nam.(Urspr.)
4
Diese Zeichnung ist unveräußerliches Eigentum der Fa. REMIS GmbH. Wir behalten uns alle Eigentum- und Vervielfältigungsrechte nach ISO 16016 vor.
Figure 1:
Roof window with outer frame
1 interior frame with fly screen
and tinting
Accessory parts:
8 affixing screws
8 cover caps
(4 slide-in elements)
• Determine the position for the roof
window on the vehicle, with respect to
6
7
No. 1 (Requirements).
width +2/-0
400 mm
Cut out the section of roof. Place the roof
window into the cut-out without the sealing
cord to check its size. There must be a gap of
a minimum of 2 mm between the roof cut-
out and the outer frame all around. Adjust
the cut-out if necessary.
2
Dateityp:
Dateiname der Zeichnung:
PART
AUSSCHNITT_VISTA
Maßstab 2:25
Allgemeintol.
Werkstück
DIN ISO
-
-kanten
Werkstoff:
2768-m-S
ISO 13715
-
Halbzeug:
Datum
Name
Benennung:
Bear.
04.03.15
-
Gepr.
04.03.15
-
Norm
Anfragestatus
-
Zeichnungsnummer:
-
(Ers.f.:)
that the sealing cord has not passed its
expiry date at the time of roof installati-
on.
8