Menu de configuration
Probe position
Navigation
Prérequis
Description
Entrée
Information
supplémentaire
Damping factor
Navigation
Prérequis
Description
Entrée
Information
supplémentaire
Gauge current
Navigation
Prérequis
Description
Information
supplémentaire
216
 Configuration → Config. étendue → Input/output → Analog IP → Probe position
Mode de fonctionnement (→  212) = RTD temperature input
Position of the temperature probe, measured from zero position (tank bottom or datum
plate). This parameter, in conjunction with the measured level, determines whether the
temperature probe is still covered by the product. If this is no longer the case, the status of
the temperature value will be ' i nvalid' .
–5 000 ... 30 000 mm
Accès en lecture
Accès en écriture
 Configuration → Config. étendue → Input/output → Analog IP → Damping factor
Mode de fonctionnement (→  212) ≠ Désactivé
Defines the damping constant (in seconds).
0 ... 999,9 s
Accès en lecture
Accès en écriture
 Configuration → Config. étendue → Input/output → Analog IP → Gauge current
Mode de fonctionnement (→  212) = Gauge power supply
Shows the current on the power supply line for the connected device.
Accès en lecture
Accès en écriture
Opérateur
Maintenance
Opérateur
Maintenance