Energizer And Fence Maintenance Chart - Gallagher M150 Notice D'installation

Masquer les pouces Voir aussi pour M150:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENERGIZER AND FENCE MAINTENANCE CHART

Fault
Energizer doesn't operate
Electric fence voltage
is below 3000V or your
stock are escaping
For more detailed fencing instruc ons refer to the Gallagher Power Fence Systems
Manual.
Save these instruc ons
14
Gallagher 3E2375 Mains Energizer User Manual
Possible Cause(s) Solution
Energizer O
Break in supply circuit
Faulty Energizer
Faulty Energizer
Inadequate grounding
Short on the fence line
Plug into power outlet.
Test power point
Have Energizer repaired
Unplug the Energizer from the
power supply and remove the
fence wire from the Red terminal.
Plug Energizer in again. Using a
Digital Volt Meter (G5030) check
the voltage across the terminals.
If the voltage is less than 5000V,
have Energizer repaired.
Improve the ground system by
adding more galvanised ground
rods to the ground system un l
the ground voltage is 200V or
below.
Check the electrical connec ons
are secure e.g. from the fence to
the red terminal, from the ground
system to the green terminal, at
gates etc. Check the voltage on
the fence every 100 (33m) using
the Digital Volt Meter. Note if the
voltage is dropping. The closer
to a fault, the lower the voltage
reading will be. Become aware
of things that cause faults and
always be on the lookout for; stray
pieces of wire on the fence, heavy
vegeta on growth, cracked or
broken insulators, broken wires.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M200M300M600M1000

Table des Matières