How To Bridge The Vario Induction Zones - Asko HI1995G Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION

How to bridge the Vario induction zones

EN 14
The Vario induction zones can be bridged (linked) to each other. This
creates 1 large zone that can be used for example for a large fish pan
or one large cooking pan.
• If the vario zones are bridged, they cannot be set to boost and the
menu functions cannot be used.
Use a (fish) pan where at least one of the centre/middle positions of the
vario zones is covered.
Activating the bridge mode
1. Place the large pan on both cooking zones so that these are both
well covered.
2. Switch the front cooking zone on.
3. Hold two keys down at the same time (for a few seconds): first
press the << button on the rear vario zone and then immediately
the >> button on the front vario zone.
'BR' will appear in the display on the rear zone. Then use the front
zone control to set a cooking level for both zones.
4. Set the desired cooking level using the + or - button, or the << or
>> button of the front zone. Both zones are heated in the level set.
Deactivating the bridge mode
1. Press simultaneously on the >> button on the front vario zone and
the << button on the very back vario zone to switch off the 'bridge'
level.
The front zone goes further on the level set in bridge function.
Or:
2. Press the on/off button of the cooking zone you want to switch off.
You will hear a beep and the level in the display disappears.
The cooking zone has been switched off completely.