Ryobi P739 Manuel D'utilisation page 9

Compresseur d'air 18 v de 3,8 l (1 gal)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

APPLICATIONS
Air compressors are utilized in a variety of air system applica-
tions. Match hoses, connectors, air tools, and accessories
to the capabilities of the air compressor.
You may use this product for the purposes listed below:
 Operating light- to medium-duty air-powered tools
 Operating air accessories such as air nozzles and
automotive tire chucks
INSTALLING/REMOVING BATTERY PACK
See Figure 1, page 13.
 Make sure the air compressor is turned off.
 Insert a fully charged battery pack into the product as
shown.
NOTE: For best performance, a 4.0 Ah battery pack is
recommended.
 Make sure the latches on each side of the battery pack
snap into place and the battery pack is secured in the
product before beginning operation.
 Depress the latches to remove the battery pack.
For complete charging instructions, see the operator's manu-
als for your battery pack and charger.
CONNECTING/DISCONNECTING AIR HOSE
(HOSE NOT PROVIDED)
See Figure 2, page 13.
WARNING:
Never exceed the air tool's pressure rating as recom-
mended by the manufacturer. When using this air com-
pressor as an inflation device, always follow the maximum
inflation guidelines stated by the manufacturer of the item
being inflated.
 Make sure the air compressor is turned off and the battery
pack is not installed.
 Rotate pressure regulator knob fully in the counter-
clockwise direction so that the outlet pressure is at
zero (0) psi.
 Attach hose with quick connect air fitting to 1/4 in. quick
coupler on air compressor. Make sure to push the hose
adaptor end fully into the coupler until the sleeve springs
forward to lock it in place.
NOTE: Your air hose can be looped around the hose wrap
brackets for storage or any time the air compressor is not
in use.
OPERATION
To disconnect an air hose or an air tool:
 Confirm that the outlet pressure is at zero (0) psi.
 When disconnecting a hose from 1/4-in. quick coupler,
always firmly hold release end of hose.
 Pull back on the release sleeve on the 1/4-in. quick
coupler.
 With a firm grip, pull out the quick-connect air fitting that
is attached to the quick coupler.
BREAK-IN PERIOD
Before first use, install a fully charged 4.0 Ah battery pack,
then run the air compressor at zero tank pressure with the
drain valve fully open for 30 minutes or until the battery pack
is completely discharged, whichever happens first.
TURNING THE AIR COMPRESSOR ON/OFF
See Figure 3, page 14.
 Install the battery pack.
 Move the Auto On/Off switch to the AUTO ON (I) position
to power the compressor on.
 To turn the air compressor off, move the Auto On/Off
switch to the OFF (O) position.
NOTE: When the compressor is in the AUTO ON (I) position,
the air compressor will automatically turn back on when
the designated tank air pressure drops below the preset
pressure limit. It will also shut off again when the cut-off
pressure is reached.
WARNING:
Never exceed the air tool's pressure rating as recom-
mended by the manufacturer. When using this air com-
pressor as an inflation device, always follow the maximum
inflation guidelines stated by the manufacturer of the item
being inflated.
WARNING:
Always ensure the switch is in the OFF (O) position and
the regulator pressure gauge reads zero before changing
air tools or disconnecting the hose from the air outlet.
Failure to do so could result in possible serious personal
injury.
9 – English

Publicité

Table des Matières
loading

Table des Matières