Other Possible Symbols In The Standard Display; Standard Settings - Stiebel Eltron SHZ 30 LCD Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
Settings
4.3

Other possible symbols in the standard display

7
e l c t r o n i
e l c t r o n i c
6
5
1 Set temperature symbol
2 Temperature limit symbol
3 Value indication relative to the active symbol
4 Service/fault symbol
5 Scale build-up symbol
6 Energy consumption symbol
7 Outlet temperature symbol
4.3.1 Scale build-up symbol
Note
If the scale build-up symbol "Ca" appears in the standard
display, we recommend descaling the flanged immersion
heater. Notify your local contractor.
4.3.2 Service/fault symbol
Note
If the service/fault symbol appears in the standard dis-
play, inform your contractor. If the symbol flashes, no
water is being heated and it is essential you inform your
contractor.
www.stiebel-eltron.com
1
c
c o m f o r t
c o m f o r t
2
3
4
4.4

Standard settings

4.4.1 Quick settings using the keys
You can make these settings directly in the standard display using
the keys.
Note
After every adjustment, the appliance switches automati-
cally to the standard display and saves the selected value.
4.4.2 Setting the set temperature
Adjust the set temperature from 20 to
85 °C using the plus and minus keys (fac-
tory setting).
Set temperature symbol appears.
If you change the set temperature of 60 °C in ECO Plus or ECO Dy-
namic mode, the energy saving mode is automatically switched to
ECO Comfort. Further information can be found in chapter "Energy
saving settings in the standard display".
4.4.3 Switching off
If you set the set temperature with the
minus key to less than 20 °C, only frost
protection remains active.
4.4.4 Rapid heating
Press the rapid heating key.
Heat-up symbol appears.
Dual circuit operation
You can switch on rapid heating with the key. A remote control
can also be installed for this purpose. The rapid heat-up function
stops and will not restart when the selected temperature has been
reached.
Manual rapid heat-up operation
You have to start the appliance with the rapid heating key. Once
the selected temperature has been reached, the appliance switch-
es off and does not restart.