Training area in mm
(for home trainer and user)
Meanings of error message codes
In case of malfunctions may adjoining list of error messages help for people to get function back. Basically, electrical repairs only in compliance with the
relevant safety rules which exists. For more information and assistance in case of malfunctions with our service department (contact details see last page.)
Error code
Possible Reason
-------
the safety lock is removed
E01
Communication abnormality: abnormal commu-
nication between the controller and the electro-
nic meter after powering on
E02
Explosion-proof protection:
E03
No sensor signal:
E05
Over-current protection:
electronic
the communication wire from the electronic
meter has no
meter to the controller is not well connected or
display.
the transformer is damaged
E09
Controller is in tilt position
Note:
Please contact your local dealer if you have checked all the
above listed things but the problem is still there.
Free area in mm
(Training area and security area
(rotating 60cm))
Solutions
1. Put the safety lock well
2. Change the safety lock switch or magnetic sensors in the computer.
3. If it's still not ok , than change the computer
1. Switch off the treadmill and plug out AC cable
2. Check each section of connection of the communication wires from the electronic
meter to the controller and ensure that all core wires are well connected.
3. Check whether wirings between the electronic meter and the controller are dama-
ged; if yes, replace the damaged wire.
1. Switch off the treadmill and plug out AC cable
2. Check whether the power supply voltage is less than 50% of the normal value.
please ensure correct voltage and test again.
3. Check whether the controller emits the odor of burning; if yes, replace the con-
troller.
4. Check whether motor wires are well connected; re-connect motor wires.
1. Switch off the treadmill and plug out AC cable
2. Check whether the sensor connector is well plugged or whether it is damaged;
plug it well or replace the sensor.
1.Check whether power supply voltage specifications is inconsistent or too low and
use correct voltage specifications for re-test.
2. System self-protection is triggered under excessive current caused by the
excessive load more than the rated value, or some place of the treadmill is jammed
so that the motor can not rotate; thus, the system start up self-protection against
excessive current under excessive load; adjust the treadmill and restart it.
3. Check whether there is over-current sound or burning odor when the motor is
running; replace the motor.
4. Check whether the controller emits abnormal odor; replace it if yes.
1. Switch off the treadmill and plug out AC cable
2. Dismantle the pillar to check connection joints on each section of the wiring from
the electronic meter to the controller.
3. Ensure that each wire core is well connected.
4. or the reason may be the communication power cord defect (damaged or broke
down); in such case, re-connect or replace wires; or replace a transformer.
1. When treadmill has incline position no start possible
2. Treadmill is not fold out complete on an even floor
3. Tilt switch at PC board has problem