= Colour calibration
Color
Calibration
(If one of the facto-
ry-calibrated DMX
modes is activated, no
other calibration can
be selected and "no
possible change in this
DMX Mode" is shown on
the display. If one of the
DMX modes with user
calibration is activated,
RAW can be selected as
an alternative calibra-
tion)
= Automatic locking of the
Autolock
controls
= LED PWM frequency
LED Fre-
quency
= Adjust fan control
Fan
= Reset to factory settings
Factory
Reset
RAW
R, G, B and W with maximum value
255
User Cali-
Individual adaptation of R, G, B, and
bration
W with values of 000 to 255 each
(across all modes)
Factory
Factory calibration of R, G, B and W
Calibration
(across all modes). Select this setting
for uniform display of the colour mac-
ros in standalone mode, as well as for
control of the colour macros via DMX.
On
Automatic locking of the controls after
approximately 1 minute of inactivity.
Display shown upon attempted use:
"Locked!"
Unlock: Press and hold UP and DOWN
simultaneously for approx. 5 seconds
Off
Automatic locking of the controls is
disabled
800 Hz /
Configuration of LED PWM frequency
1200 Hz /
2000 Hz /
3600 Hz /
12 kHz / 25
kHz
Auto
Automatic adjustment of the fan
performance
Max. Inten-
Maximum fan capacity for maximum
sity
brightness
Low Noise
Extra-quiet fan with reduced bright-
ness
Reset to factory settings: ENTER ->
"Reset Now!" -> ENTER