Status Symbols - ROBBE POWER PEAK INFINITY 2 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CYCLE No. 14
tery is currently being charged in CHAR => DISC mode (C/D, C).
3. Variable parameter displays
The purpose of these displays is to provide information when you
are programming the charge parameters. At the end of the line
you will see alternating '+' and '-' symbols, which indicate that
you can alter this value using the '+' or '-' button.
However, you can only ever change the parameter in the top line
of the screen.
== BUZZER ==
= NO BUZZER =
D.P.
NORMAL
D.P. SENSITIVE
change the setting.
MANUAL CUR.SET
AUTOMATIC C.S.
SET CHAR 4.00A
Operating instructions
POWER PEAK INFINITY 2
Display of the current
cycle during a balan-
cing process. At pre-
sent the 14th cycle is
C/D,C
in progress. The bat-
Display for switching
the piezo buzzer on
+
and off. Press the '+'
-
or '-' button to reverse
the setting.
+
-
Display for toggling
Delta Peak sensitivity
+
between 'normal' and
-
'sensitive'. If you sel-
ect 'sensitive', the
charger
terminates
+
the charge slightly
-
earlier
than
'normal' is set. Press
the '+' or '-' button to
Display for selecting
manual or automatic
+
current setting. If you
-
set
'AUTOMATIC
C.S.',
the
shows 'AUTO' in the
'SET CHAR', 'SET
+
DISC', 'S.DC CUT'
-
and 'S.M.CUR' dis-
plays instead of the
variable parameter;
the automatic circuit
sets
the
values for you.
Display for setting the
+
charge current within
-
the range 0.1 A and
max. 5 A, using the
'+/-' buttons. The cur-
rent presently set is
4.00 A. Press the '+'
or '-' button to change
the charge current.
If you have selected Automatic mode, you cannot set the charge
current manually.
Note: in any case the charger will not allow you to change the
current setting in the period shortly before the Delta Peak char-
ge termination trips.
SET DISC 2.50A
discharge current presently set is 2.50 A. The charger is ready to
use; the discharge process can be started by pressing the
'START-STOP' button. In Automatic mode the software calcula-
tes and sets the optimum discharge current for you.
S.DC.CUT 7.86V
value presently set is 7.86 V. The charger is ready to use; the
discharge process can be started by pressing the 'START-STOP'
button. In Automatic mode the software calculates and sets the
optimum final discharge voltage for you.
S.M.CUR. 100mA
are 0, 50, 100, 150 and 200 mA. The value presently set is 100
mA. In Automatic mode the software calculates and sets the opti-
when
mum trickle charge current for you.
S.PAUSE
the range 0 to 10 minutes. The value presently set is 3 minutes.
screen
The charger is ready to use; the charge process can be started
by pressing the 'START-STOP' button.
You can 'leaf through' the individual screen displays shown here
in both directions, i.e. forwards and backwards.
Pressing the bottom display button writes the parameters from
correct
the bottom line of the screen to the top line; in the top line you
can change the settings to your preferred values.
Press the top button to switch the screen back, i.e. to move the
previous parameter back to the top line.
All screen displays are arranged in an endless loop.

Status symbols

It is clearly important that you are aware of the current status of
the POWER PEAK INFINITY 2 at all times, and you can check
this by looking at the symbols displayed in the right-hand corner
of the screen. The list below is a brief key to these symbols.
7
Order No.
8294
Display for setting the
discharge current wit-
+
hin the range 0.1 A to
-
max. 5 A, using the
'+/-'
buttons.
Display for setting the
final discharge volta-
+
ge within the range
-
R
0.01 V to 50 V, using
the '+/-' buttons. The
Display for setting the
+
trickle charge current
-
using the '+/-' buttons;
the possible values
Display for setting the
3 MIN
pause between char-
+
ge / discharge phases
-
R
in cycle mode; possi-
ble times are within
The