Operation
(4) In sleeping set or modification state, if there is no operation in 10 seconds, it will keep previous
state, and the setting or modification is invalid this time.
(5) Under sleeping and timer setting state, it will display setting time respectively; when setting
simultaneously, it will display the prior executed time. When timer off is executed first, sleeping function
will be cancelled and when sleeping is executed first, then timer off function will be operated after that.
(6) Under function setting state, it will exit function setting state by pressing
 or 
 key.
(7) Sleeping time and timer on should not be set at the same time.
(8) When setting sleeping function, press ON/OFF key to quit sleeping set and turn off unit.
Heat Reclaim Ventilation Function
(1) Press
 key to enter function setting, press 
 to the heat reclaim ventilation icon " 
" and 
it will flash, press 
 key again to confirm the operation. The above operation can cancel the heat 
reclaim ventilation function if heat reclaim ventilation function has been set.
(2) After you set heat reclaim ventilation function, change mode of wired controller, heat reclaim
ventilation function is kept and heat reclaim ventilation function will be memorized when non-volatile
memory valid.
Switch between Fahrenheit and Celsius
(1) If the current temperature is displayed in Celsius, set temp. should be adjusted to 30°C in each
mode(when energy saving function is set currently, the heating mode will be the highest limit value of
the energy saving function). Then press   key for 15s to switch to Fahrenheit, the interface will display
86°F (when energy saving function is set, its highest limit value of Fahrenheit will be displayed).
(2) If the current temp. is displayed in Fahrenheit,set temp. should be adjusted to 60°F in each
mode(when energy saving function is set currently, the cooling/dry mode will be the lowest limit value
of the energy saving function). Then press   key for 15s to switch to Celsius, the interface will display
16°C (when energy saving function is set, its lowest limit value of Celsius will be displayed).
14