with the variants Lift 1 and Lift 2. No direct height
adjustment feature is available for the Fix variant.
Fix
5.2.1
variant
The desk has a fixed height of 740 mm. With the
exception of height adjustment for uneven floors, the
desktop height cannot be adjusted.
5.2.2 Variants
The electric motor enables variable vertical desk
adjustment to between 720 mm and 1200 mm (Lift 1
variant) or to between 650 mm und 1250 mm (Lift 2
variant).
Make sure before first use that
the desk has been assembled correctly;
the controller is connected to the motor by cable;
the control panel is connected to the controller;
all safety-relevant information has been followed.
For the power connection
Insert the mains plug into a power point
supplying 220/230 V.
EN
Prior to putting the desk in service, it is
necessary to perform a manual reset.
The instructions for this procedure can be
found in the description of the
corresponding control panel.

5.2.3 Up/Down control panels

The control panel is located on the left- or right-hand
side at the underside of the desktop.
Fig. 5-2: Up/Down control panel version
12
Lift 1
Lift 2
and
Operating and adjusting
ATTENTION
Risk of damage to control panel!
Do not lean on the control
panel.
Do not place any objects on the
control panel.
Do not pour liquids over the
control panel.
Height adjustment – Up/Down control panel
Press the respective "Up or Down" button
to reach the desired desktop height.
The desktop moves up or down.
=
Release the "Up or Down" button.
The desktop stops at the desired point.
=
Manual desktop reset
Wait for 5 seconds if the desk has just been
connected to the mains.
Press and hold the "Down" button until the
lower end position is reached.
Continue to hold the "Down" button for at
least 3 seconds.
The resetting and initialisation process is
=
starting.
After conclusion of the resetting and
initialisation process, press the "Up" button.
The desired height is reached.
=
If the control panel is released before the
process is completed, the manual
resetting process will be interrupted and
must be restarted.