5.3 Control elements

The operating elements and connectivity are located on the front side of the filter
component
-
I / 0 button (pos. 1)
Use this switch to turn the filter system on or off.
The green illuminated ring around the switch indicates trouble-free operation
of the filter system. If anyissue or error is encountered, the green light turns off
and the filter system automatically switches off.
-
Signal light (pos. 2)
The yellow signal light indicates an issue or an error in the filter system.
For visual display, the error is presented using varying blink codes.
Signal light flashes evenly at regular intervals:
- It is necessary to service the equipment, please inform the
KEMPER service.
Signal light flashes 2 times shortly in succession at regular intervals:
- If a failure of the frequency converter occurs, inform of it the
KEMPER service department.
Signal light flashes 4 times shortly in succession at regular intervals:
- Compressed air failure, check for sufficient supply of compressed air.
-
Manual dust removal (pos. 3)
Use this button to manually start the discharge. Pressing it again will stop
the process.
-
"IFA" measuring connection (pos. 4)
Intended only for KEMPER service.