Remove the sticking tape with which hoses/cables are attached in the filtration
unit.
Now connect the grounding cable (pos. 1, B) to the corresponding grounding
screw (pos. 1, A) on the cyclone.
In the next step, both hoses for supply of compressed air in the discharging
system (pos. 2, B) are to be put on the unused adapters of compressed air on
the 3/2-way valve (item 2, A).
Finally, connect the compressed air supply hose (pos. 3, B) to the pressure
regulator (pos. 3, A).
As a last step, the delivery hoses are attached to the cyclone using hose
clamps. Please ensure that both hoses are in the specified position, otherwise
no delivery or discharge will be possible Close the delivery hose (pos. 4, B,
NW 28) on the upper output of the cyclone (pos. 4, A). Then attach the second
hose (pos. 5, B, NW 20) to the input of the cyclone (pos. 5, A).
Attach the service cover.
As a last step, close the pressurised air supply at pos. 7 and the power supply
at pos. 6.