Remove the sticking tape with which hoses/cables are attached in the filtration
●
unit.
Now connect the grounding cable (pos. 1, B) to the corresponding grounding
●
screw (pos. 1, A) on the cyclone.
In the next step, both hoses for supply of compressed air in the discharging
●
system (pos. 2, B) are to be put on the unused adapters of compressed air on
the 3/2-way valve (item 2, A).
Finally, connect the compressed air supply hose (pos. 3, B) to the pressure
●
regulator (pos. 3, A).
As a last step, the delivery hoses are attached to the cyclone using hose
●
clamps. Please ensure that both hoses are in the specified position, otherwise
no delivery or discharge will be possible Close the delivery hose (pos. 4, B,
NW 28) on the upper output of the cyclone (pos. 4, A). Then attach the second
hose (pos. 5, B, NW 20) to the input of the cyclone (pos. 5, A).
Attach the service cover.
●
As a last step, close the pressurised air supply at pos. 7 and the power supply
●
at pos. 6.
Serial No.: 150 2206
Technical modifications without previous notification and errors reserved.
KEMPER CleanAirTower Instruction manual - EN
Figure 6, grounding and pneumatic system
- 59 -
Rev.: 2
Status as of:
09/2015