Technical data
Switch-off time
Displays
Connections
Power supply type
Operating voltage
Power consumption,
maximum
Power consumption,
maximum
Power consumption,
nominal
Power consumption,
typical
36 |
E N
The device will be automatically muted after three minutes when in
battery mode
3 status LEDs for software status and signal strength
12 V DC IN
Screw terminal
BATT1 and BATT2
2 battery compartments with space for 2 batteries each
Type B (EN 50131-1:2006 + A1:2009 + A2:2017 Section 9 and
EN 50131-6:2017 Section 4.2) for external power supply via power
supply unit and batteries inserted as a backup power supply.
Type C (EN 50131-1:2006 + A1:2009 + A2:2017 Section 9 and
EN 50131-6:2017 Section 4.2) for pure battery operation without
external power supply via power supply unit.
Power supply compliant with EN 50131-1:2006 + A1:2009 + A2:2017
9.2 and EN 50131-6:2017 if installed correctly together with Secvest
FUAA50xxx.
6 – 15 V DC, 12 V nominal (external power supply unit) and 6 V DC
(batteries)
or
6 V DC (batteries), 4,4-6V DC
I DC maximum:
100 mA @ 12 V DC
Defined by:
Piezo sounder on
full volume
Standby current
12 mA @ 12 VDC
Defined by:
RXTX on, Piezo sounder off
0.144 W
0.144 W x 24 h x 365 = 1261 kWh per year
Standby current
30 uA @ 6 V DC (batteries)
Defined by:
RXTX off, Piezo sounder off