RUCK REQUIREMENTS
WARNING: Rated capacity of the truck/attach-
ment combination is a responsibility of the
original truck manufacturer and may be less than
that shown on the attachment nameplate.
Consult the truck nameplate.
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
Min.
22E, 33E,
19 L/min.
45E
¿
Cascade E-Series Clamps are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606
or MIL-0-2104B. Use of synthetic or aqueous base hydraulic
fluid is not recommended. If fire resistant hydraulic fluid is
required, special seals must be used. Contact Cascade.
¡
Flow less than recommended will result in reduced system
performance.
¬
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Carriage Mount Dimension (A)
A
Class 2
Class 3
GA0028.eps
Auxiliary Valve Functions
Check for compliance with ANSI standards:
GA0082.ill
¿
¡
Recommended
28 L/min.
Minimum
Maximum
380.0 mm
381.0 mm
474.5 mm
476.0 mm