Single and Three Phase Wire Diagram
Use wiring diagram on motor plate if different from below.
Wiring should always be done by a licensed electrician!
- Electrically insulate all connections.
- For counter-clockwise rotation, looking from top of motor down.
7.5hp Three Phase
Baldor Motor / 208 - 230/460v / 19 - 17/8.6 amps / TEFC / C Face / 3450 rpm
208 / 230 Volts
1 & 7
L1
2 & 8
L2
3 & 9
L3
4
Tie Together
5
6
To reverse rotation interchange any two line leads.
Check rotation after wiring.
Wire for counter-clockwise rotation.
OAS three phase systems are
wired for 240 volts. Additional
components are needed for
460 volt requirements. See Pg.
17 for details.
460 Volts
1
L1
2
L2
3
L3
Tie Together
7 & 4
Tie Together
8 & 5
Tie Together
9 & 6
12
Motor
Wire
Box
Green
Chassis
Screw
Ground: Connect house ground
wire to green chassis screw in
motor wire housing box.