Cleaning Of The Filter - Disan ZSA 18/1 Manuel D'utilisation

Masquer les pouces Voir aussi pour ZSA 18/1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Impianti aspirapolvere centralizzati
Zentralstaubsauganlagen
Central vacuum systems
Système d'aspiration centralisée
5. Carefully place the waste container
up to the bottom of the machine in
order to make a good seal.
(Close both clamps together)

CLeANING Of THe fILTer:

Before touching the cleaner pay
attention to its temperature, which
due to the motor can be high.
Wait until the cleaner is cold from the
surrounding temperature.
For a perfect operation of the system,
particular attention should be paid to
the condition of the filter inside the
vacuum unit. It must be checked and
cleaned if necessary every 2 or 3
months or if a loss of power is noticed.
1. Uncouple the waste unit from the
machine
2. Rotate the finger grip anticlockwise
until the filter can be removed.
3. Extract the filter (for model: 45/2-3
also the metal grill) and proceed to
clean it using a compressor, tradi-
tional vacuum or by a simple shak-
ing motion, being careful not to
damage it.
Z 119
4. Check that the metal motor protec-
tion grill is not damaged or dirty.
Z 121
5. Replace the filter into the machine
case an retighten the knurled nut.