MiniAir20
Special functions on switching on:
The instrument switches to the special mode if the following keys are held
pressed while switching on:
Keys:
Functions:
Setting the desired averaging time
If the "Rep" key is already pressed on switching on with
the "On/Off" key (simultaneously), the indication will show
the maximum averaging time of 7200 seconds.
This maximum value can then be reduced in 1800 second
+
steps with the "Rep" key.
Example: You require an averaging time of 60 min. (3600 sec.)
By pressing the key "Flow" or "Temp" you return to the
measuring mode.
This averaging time remains saved in the "Rep" key until it is
overwritten or the instrument is switched off.

Indication:

Normally the display of the indication unit shows a 2 sec. mean value which is
renewed every 0.5 sec.
36
With an indication of 7200 sec., press the key "Rep"
twice (indication 3600)